Genuine Fluke laser range finder F411D 414D 419D 424D

Genuine Fluke laser range finder F411D 414D 419D 424D
 

Product description:

Product parameters:

  • Brand: FLUKE / Fluke
  • Model: 411D
  • Item: Industry
  • COLOR CLASS: 411D 414D 419D 424D
  • Decoration and construction content: installation works
  • How it works: Laser
  • Distance measuring distance: 30M


Buy Fluke any product to send a practical computer mouse pad, first come first served!

Technical Parameters
Distance (for longer distances, use one target)
Fluke 411D 0.1 m to 30 m
(0.33 ft to 100 ft)
Fluke 416D 0.05 m to 60 m
(0.16 ft to 200 ft)
Fluke 421D 0.05 meters to 100 meters
(0.16 to 330 feet)
Measurement accuracy
Fluke 411D * ± 3 mm (0.118 in)
Fluke 416D ** ± 1.5 mm (± 0.059 in)
Fluke 421D ± 1.5 mm (± 0.059 in)
Laser level
Fluke 411D Class II
Fluke 416D Class II
Fluke 421D Class II
Laser type
Fluke 411D 635 nm, <1 mW
Fluke 416D 635 nm, <1 mW
Fluke 421D 635 nm, <1 mW
Automatic power off
Fluke 411D After 180 seconds
Fluke 416D After 180 seconds
Fluke 421D After 180 seconds
Continuous measurement
Fluke 411D Yes
Fluke 416D Yes
Fluke 421D Yes
Plus / minus
Fluke 411D Yes
Fluke 416D Yes
Fluke 421D Yes
Battery Life
Fluke 411D Up to 3000 measurements
Fluke 416D Up to 5000 measurements
Fluke 421D Up to 5,000 measured values
LCD lighting
Fluke 411D no
Fluke 416D Yes
Fluke 421D Yes
The data location
Fluke 411D no
Fluke 416D 10
Fluke 421D 20
Minimum / maximum value
Fluke 411D no
Fluke 416D Yes
Fluke 421D Yes
Sound feedback
Fluke 411D no
Fluke 416D Yes
Fluke 421D Yes
Pythagorean function (indirect measurement)
Fluke 411D simple
Fluke 416D all
Fluke 421D complete
Degree of protection
Fluke411D IP40
Fluke 416D IP54
Fluke 421D IP54
size
Fluke 411D 123 mm x 50 mm x 26 mm
(4.84 in x 1.97 in x 1.02 in)
Fluke 416D 135 mm x 46 mm x 31 mm
(5.31 in x 1.81 in x 1.22 in)
Fluke 421D 127 mm x 52 mm x 29 mm
(5.00 inches by 2.06 inches by 1.13 inches)
weight
Fluke 411D 150 g (5.29 oz)
Fluke 416D 110 g (3.88 oz)
Fluke 421D 125 grams (4.40 ounces)
temperature range
Fluke 411D Storage: -25 ° C to 70 ° C (-13 ° F to 158 ° F)
Operating: 0 ° C to 40 ° C (32 ° F to 104 ° F)
Fluke 416D Storage: -25 ° C to 70 ° C (-13 ° F to 158 ° F)
Operating: 0 ° C to 40 ° C (32 ° F to 104 ° F)


Fluke 421D



-25 ° C to 70 ° C (-13 ° F to 158 ° F)

0 ° C to 40 ° C (32 ° F to 104 ° F)
Use altitude
(ISO 9022)
Fluke 411D Up to 3500 m
Fluke 416D Up to 3500 m
Fluke 421D Up to 3500 meters
Storage humidity
(At 35 ° C)
Fluke 411D Up to 85% (24 hours)
Fluke 416D Up to 85% (24 hours)
Fluke 421D Maximum 85% for 24 hours
battery
Fluke 411D AAA (2)
Fluke 416D AAA (2)
Fluke 421D AAA (2)

* Up to 10 m (33 ft) under favorable conditions (best target surface, room temperature) Under adverse conditions (eg strong sunlight, weakly reflecting target surfaces or large temperature fluctuations), distances of 10 m (33 ft) or more, the measurement accuracy may decrease to approximately ± 0.25 mm / m (± 0.003 in / ft).

** Up to 10 m (33 ft) under favorable conditions (best target surface, room temperature). Under adverse conditions (eg strong sunlight, weakly reflecting target surfaces or large temperature fluctuations) The deviation at m (33 ft) may be increased by approximately ± 0.15 mm / m (± 0.0018 in / ft).

The 414D reduces errors, saves time and reduces costs.
characteristic:
  • Measuring the distance of the most advanced laser technology
  • With one-touch operation, the distance between two objects can be measured instantly
  • Measuring distances up to 50 m (165 ft) with an accuracy of 2 mm (0.08 in)
  • Even at longer distances, bright lasers can be easily positioned
  • Fast calculation of area (sq ft / m) and volume
  • Simple addition and subtraction operation
  • Using the other two measurements, the Pythagorean theorem can be used to measure the height indirectly
  • Up to five measurement results can be stored
  • Battery life for 3000 measurements, with auto-off function
  • Two lines, and has a continuous display (until the next button)
  • The carrying bag is secured to the tool band
  • Powered by two AAA batteries
All of the above instruments have the following functions and advantages:
  • Reduce the estimation error, save time and cost
  • Measuring the most advanced level 2 laser technology
  • Just one-touch operation to complete real-time measurements
  • Simple addition and subtraction operation
  • Quickly calculate area (building area) and volume
  • Addition and subtraction measurements are simple and convenient
  • Min / Max function
  • The auto-off function increases battery life
  • The distance from the other two measuring points is indirectly determined by the Pythagorean method
  • Carrying bag with Fluke logo
  • Three-year warranty


414D 419D 424D
Distance measurement
Typical measurement tolerances (1) ± 2.0 mm (3) ± 1.0 mm (3)
Maximum measuring tolerance (2) ± 3.0 mm (3) ± 2 mm (3)
Leica GZM26 Position of the target board 50 m (165 ft) 80 m (260 ft) 100 m (330 ft)
Typical Range (1) 40 m (130 ft) 80 m / 260 ft 80 m (260 ft)
Range under adverse conditions (4) 35 m (115 ft) 60 m / 195 ft 60 m (195 ft)
The smallest unit to display 1 mm / 1/16 in 6/30/60 mm
(10 / 50 / 100 m)
∅ The distance of the laser spot 6/30/60 mm
(10 / 50 / 100 m)
6/30/60 mm
(10 / 50 / 100 m)
Tilt measurement
Laser beam measurement tolerances (5) no no ± 0.2°
Tolerance of case measurement (5) no no ± 0.2°
range no no 360°
general
Laser level 2
Laser type 635 nm, <1 mW
Degree of protection IP40 IP54
Laser cut off automatically After 90 seconds
Automatic shut-down After 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A / IEC LR03 Up to 3,000
Measurement results
Up to 5,000
Measurement results
Dimensions (H x W x L): 116 mm length
53 mm width
33 mm depth

127 mm length
56mm width
33 mm depth

127 mm length
56mm width
33 mm depth

Weight (with battery) 113 g 153 g 158 g
Temperature range: Storage operation -25 ° C to + 70 ° C (-13 ° F to +158 ° F)

0 ° C to +40 ° C
(32 ° F to +104 ° F)


-25 ° C to + 70 ° C (-13 ° F to +158 ° F)

-10 ° C to +50 ° C
(14 ° F to +122 ° F)


Calibration cycle Not applicable Not applicable Tilt and compass
Maximum height 3000 m 3000 m 3000 m
Maximum relative humidity Lt; 0 & gt; F to 120 & lt; 0 & gt; F
(-7 ° C to 50 ° C), 85%
Lt; 0 & gt; F to 120 & lt; 0 & gt; F
(-7 ° C to 50 ° C), 85%
Lt; 0 & gt; F to 120 & lt; 0 & gt; F
(-7 ° C to 50 ° C), 85%
Safety IEC Standard Number 61010-1: 2001
EN60825-1: 2007 (Class II)
Electromagnetic Compatibility (EMC) EN 55022: 2010
EN 61000-4-3: 2010
EN 61000-4-8: 2010

(1) Suitable for 100% target reflectivity (white wall), low background lighting intensity, 25 ° C.
(2) for 10% to 500% of the target reflectivity, high background lighting intensity, -10 ° C to +50 ° C.
(3) The tolerances apply from 0.05 m to 10 m and the confidence level is 95%. The maximum tolerance may be less than 0.1 mm / m at distances of 10 m to 30 m and tolerances of less than 0.15 mm / Lt; / RTI & gt;
(4) Suitable for 100% target reflectivity with background illumination from 10'000 to 30,000 lux.
(5) After user calibration, the extra angle in each quadrant causes a deviation of ± 45 °, ± 0.01 ° per degree, for room temperature, and the maximum value deviation increases by ± 0.1 ° for the entire operating temperature range.



416D and 411D laser range finder provides:

Reduce estimation errors, saving time and costs

Using advanced distance measurement laser technology

Instantaneous measurement of the distance between two objects with one-button operation

The target is easily aligned by a bright laser beam

Measurements up to 30 m (100 ft) in 3 mm (0.12 in) accuracy

Distance formulas are quickly calculated, such as area (square feet per square meter) and volume

Easy distance addition and subtraction calculation

Indirect measurements can be made using the Pythagorean function and two other measured values

Automatic power off function to extend the battery life

The display hold function makes it easier to view in hard-to-reach areas

Battery: two AAA

A carrying pocket that can be secured to the tool holder

Two-year warranty