[Electronic and Electrical] - [LED equipment]

Ming - wai rail power supply DR - 100-12 100W 12V7.5A jingmeilipinpaisongzhong...

Product code: -6991000030
Unit price 20.62$
Sold quantity 157
Available stock 149
Expired or Cancelled

Product parameters:

  • Brand: MW / Ming-wai
  • Model: DR-100-12
  • Modulation: Pulse width modulation
  • Connection: full-bridge
  • Function: Power transformer


■ Product description

Suitable for installation in DIN rail TS35 / 7.5 or 15. No ground wire (Class II), double insulation, is a low-voltage switchgear, and is suitable for the construction of building automation and automation of household electrical appliances rail power supply, quick and easy installation, and small circuit breaker as the ladder-type appearance, Low idle standby loss models.

■ Main features
Universal universal AC input voltage
Mounted on DIN rail TS35 / 7.5 or 15
No-load loss <1W (meets ENERGY STAR requirements)
Short circuit protection / overload protection / over-voltage protection /Overheat protection
International Safety Certification UL / CUL / TUV / CB / CE
Class II insulation class
Shanghai Lez Technology Development Co., Ltd. Production
LED indicates the operating status
Natural ventilation cooling
100% full load burn-in test
Lead-free process, in line with environmental RoHS requirements
Taiwan Ming-wai brand, Suzhou factory production
3 year warranty
■ The main parameters
DC output range 12V, 0 ~ 7.5A
Output voltage accuracy ±2%
Ripple 120mV
effectiveness 87%
Input voltage range 88 to 264 VAC / 124 to 370 VDC
Input inrush current Cold start 45A / 230V
Voltage adjustment range 12V: 12-15V, 15V: 15-18V, 24V: 24-29V
Overload protection Over-current point of 105% to 135% when the constant current limit automatically restored
Over-voltage protection The rated output voltage of 125% to 155% off, restart reset
Overheat protection 95 ℃ ± 15 ℃ (RTH2 detection power transistor radiator temperature), protection type: thermal shutdown, automatic recovery after temperature drop
Start Rise Hold Time 230VAC full load 2700ms, 80ms, 50ms
Lezi home franchise stores All rights reserved
Insulation properties Between input and output: 3KVac
Operating temperature -20 to + 60 ° C (see output derating curve)
Anti-vibration 10 to 500Hz, 2G 10 minutes / cycle, XYZ each axis for 60 minutes
Safety Certification Through UL60950-1, TUV60950-1 certification, according to EN50178 design
Electromagnetic Compatibility Standard Emissions: EN55011, EN55022 (CISPR22) class B, harmonics: EN61000-3-2, -3
Electromagnetic Compatibility Standard Anti-interference: EN61000-4-2,3,4,5,6,8,11, ENV50204, ENV55024, EN61000-6-2, EN61204-3,Class A heavy industry standard
Mean time between failures ≥ 486,000 hours, MIL-HDBK-217F (25 ℃)
Wiring Input: 3 points Output: 4-point screw DIN terminal
Chassis number 970A
Dimensions 100 × 93 × 56mm (width × height × depth)
Weight and packaging 0.35 kg / only; 36 per box / 13.6 kg, 0.0252 cubic meters

Installation instructions

model:
Shell type switching power supply

Description:
Shell-type power supply includes a metal shell and plastic shell models, the internal PCB board is wrapped by the shell, usually installed in the system cabinet.Mingway power supply according to the power rating and design concept is divided into two different types: one is built-in Cooling fan, and the other is without a fan.

installation:







1. Before installation or maintenance work, disconnect the power supply from the application system and ensure that it is not automatically reconnected without notice!
2. Please ensure that the mounting screws are at a safe distance from the internal components of the power supply. Please refer to the housing diagram on the sample manual for the most suitable mounting screws. 'Buy a power supply.
3. The non-standard mounting direction or the power supply operating at high ambient temperature will cause the internal components of the power supply to rise in temperature and should be used for derating applications. Good work load.
4. Fans and vents should not be obstructed. If there are other heat sources nearby, keep at least 10-15 cm
5. The recommended wire sizes are as follows
AWG 18 16 14 12 10 8
Rated current (A) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Wire cross-sectional area (mm square) 0.75 1.00 1.5 2.5 4 6
Note: The maximum surge current is only applicable to 1-4 core, 5 core surge current can not exceed the rated current of 80%
Make sure that all wires are wired in the terminal block and that the terminal screws are tightened to prevent poor contact.
6. Additional information about the product can be found on this website

Warning !!

1. To prevent electric shock and burn risk, all power supply faults should be checked by a qualified electrician. It is strictly forbidden to remove the power supply case.
2. Do not install the power supply in a humid environment or near water.
3. Do not expose the power source to high temperatures and near sources of ignition. Refer to the specifications to determine the maximum ambient temperature for the power supply application.
4. The output voltage and output current can not exceed the ratings specified in the specifications.
5. The ground wire (FG) must be connected to the ground. 'Buy a power supply to find Lezi with Mingwei'. If you have any questions, please call 400 600 0430.
6. Since all power supplies are part of the application system, when the power supply is integrated into the application system, the EMC of the final system will need to be re-tested to confirm that the power supply is only one part of the application system,