[Electronic and Electrical] - [LED equipment]

Mingwei PFC power supply SP-240-24 240W 24V10A (an authorized dealer with tax)

Product code: -47431600030
Unit price 40.29$
Sold quantity 137
Available stock 190
Expired or Cancelled

Product parameters:

  • Brand: MW / Ming-wai
  • Model: SP-240-24
  • Modulation: Pulse width modulation
  • Connection: full bridge
  • Function: Power transformer


■ Optional accessories
■ Product description

High power factor power supply models are the preferred models for export to Europe. Built-in active power factor correction circuit (PFC) is conducive to improving energy efficiency and reduce harmonic interference, the global full range of voltage input, functional integrity

■ Key features
Universal universal full range of AC input voltage
Built-in active power factor correction circuit, power factor: 115VAC PF> 0.96; 230VAC PF> 0.93
With short circuit protection / overload protection / overvoltage protection /Overheating protection
International Certification: UL / TUV / CB / CE
Shanghai Lezi Technology Development Co., Ltd. Production
The DC fan is forced to cool by the built-in speed control
90KHz fixed switching frequency
The LED indicates the operating status
Efficient, long life, high reliability
100% full load aging test
Lead-free process, in line with environmental protection RoHS requirements
Taiwan Mingwei brand, Suzhou factory production
3 year warranty
■ The main parameters
DC output range 24V, 0 ~ 10A
Output voltage accuracy ± 1%
Ripple 150mV
effectiveness 87%
Input voltage range 85 ~ 264VAC / 120 ~ 370VDC
Input inrush current Cold start, 230V at 230V
Voltage adjustment range Rated output voltage ± 10%
Power Factor PF> 0.93 / 230VAC; PF> 0.98 / 115VAC (at full load)
Leakage current <2mA / 240VAC
Overload protection Over-current point in 105% to 135%, automatic detection, automatic recovery
Over-voltage protection Rated output voltage of 115% to 120% off the output voltage, restart recovery
Overheating protection 85 ℃ ± 5 ℃ (transistor heat sink temperature) when the turn off, after the temperature is automatically restored
Start rising hold time 230VAC full load time 800ms, 50ms, 20ms
Lez home franchise stores All rights reserved Do not copy
Insulation characteristics Between input and output: 3KVac, between input and housing: 1.5KVac, between output and housing: 0.5KVac, 1 minute
Operating temperature -20 to + 70 ° C (see output drop curve)
Anti - vibration 10 to 500 Hz, 2 G 10 min / cycle, XYZ each axis for 60 minutes
Safety certification Pass UL60950-1, TUV EN60950-1 certification
Electromagnetic compatibility standards Launch: EN55022 (CISPR22) class B Harmonics: EN61000-3-2, -3
Electromagnetic compatibility standards Anti-interference: EN61000-4-2,3,4,5,6,8,11, ENV55024, Class A light industry standard
Mean time between failures ≥284,000 hours, MIL-HDBK-217F (25 ℃)
Wiring 7P / 9.5mm with cover terminal block
Dimensions 190 × 93 × 50mm (length × width × height)
Shell number 987A
Weight and packaging 0.8 kg / only; each box 18 / 15.4 kg / 0.0294 cubic meters

■ Optional paperback method
■ Optional rail mounting method 1

Installation guidelines

model:
Shell type switching power supply

Description:
The housing power supply includes a metal housing and a plastic housing. The internal PCB is wrapped in a housing and is usually installed in a system cabinet. The plain power is divided into two different types depending on the rated power and design concept of the power supply: Cooling fan, the other is without a fan.

installation:







1. Before installing or performing maintenance work, disconnect the power supply from the application system and make sure that it does not automatically reconnect without notice!
2. Please attach the mounting screws to the internal components of the power supply to maintain a sufficient safe distance. Please refer to the package on the sample manual for the most suitable mounting screws. 'Buy the power supply for the use of Mingwei', please call 400 600 0430.
3. The non-standard installation direction or the power supply operating at high ambient temperatures will cause the temperature of the internal components of the power supply to rise and should be used in the load. Please install according to the optimum mounting direction of the specifications and determine the power supply according to the temperature- Good work load.
4. Fans and vents should not be obstructed by anything. If there are other heat sources nearby, keep at least 10-15 cm
5. The recommended wire sizes are as follows
AWG 18 16 14 12 10 8
Rated current (A) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Wire cross-sectional area (mm square) 0.75 1.00 1.5 2.5 4 6
Note: The maximum surge current is only applicable to 1-4 core, 5 core surge current can not exceed the rated current of 80%
Ensure that all wires of the wire are in the terminal block and that the terminal screws are tightened to prevent poor contact.
6. Additional information about the product can be found on this website

Warning !!

1. To prevent electric shock and burn risk, all power supply faults should be checked by a qualified electrician.
2. Do not install the power supply in a humid environment or near water.
3. Do not expose the power supply to high temperature environments and near fire sources. Please refer to the specifications to determine the maximum ambient temperature for power applications.
4. The output voltage and output current can not exceed the ratings specified in the specifications.
5. The ground wire (FG) must be connected to the ground. 'Buy the power supply for the use of Mingwei', please call 400 600 0430.
6. All Mingwei power supplies are designed according to EMC specifications, and we can provide test reports of the relevant power supply. Because the power supply is only a part of the application system, the EMC of the final system needs to be tested again when the power is integrated into the application system