UPS Power Supply 12V 100AH ​​battery UPS backup power | 12V maintenance-free lead-acid battery

UPS Power Supply 12V 100AH ​​battery UPS backup power | 12V maintenance-free lead-acid battery
 

Product description:

Product parameters:

  • Condition: New
  • Brand: Luo Jun
  • Model: 12V100AH


Luo Jun UPS battery 12V 100AH ​​UPS power supply Maintenance-free lead-acid Battery

'Product name'Luo Jun Valve - regulated seal maintenance - free lead - acid battery
'type number'6-GFM-100
'Capacity the amount'12V / 100AH

Luo Jun UPS Maintenance-free lead-acid battery power by "GB / T Standard for Valve - Regulated Lead Acid Batteries "Design and manufacture, the product before use without adding water, the user can only be properly installed to use. No acid leakage, low resistance, resistance to vibration, anti-over-discharge recovery ability, self-discharge, long life And so on.

Product Image:

Baby Features:
Equipment, close, No leakage, no acid pollution ;No specific environment to use; no need to add water, no need to add electrolyte, Maintenance-free ; Connection is convenient, no specific direction to use; internal resistance is small, Output power is high ; Low-impedance design, low self-discharge, capacity retention and storage time 20Release 12Month or more; CCDS Charge and discharge detection system to ensure product consistency ;Using high-strength engineering plastics as raw materials and high-density ultra-fine glass fiber separator to ensure that the battery-class quality; to adapt to various temperature conditions-1545) ;No free electrolyte, explosion-proof, self-discharge small.

model

Voltage

capacity

Reference weight

Dimensions

(V)

(Ah)

(Kg)

L * W * H (mm)

6-GFM-7

12

7

2.1

115*65*94

6-GFM-17

12

17

5.5

180*77*167

6-GFM-24

12

24

8.5

165*125*175

6-GFM-38

12

38

11

197*165*175

6-GFM-65

12

65

18

350*166*175

6-GFM-100

12

100

28

407*173*210

Performance and Benefits:
Safety and high reliability
The use of automatic safety valve (VRLA ), To prevent the gas from being sucked into the battery to affect its performance, but also to prevent the gas generated by charging and other internal pressure caused by abnormal damage to the battery.Full sealed batteries in the normal float will not have electrolyte and acid mist discharge. , The use of independent patented technology battery tray and supporting the use of batteries to ensure more safe use of battery.

long lasting
in 20Environment, FM Series of small sealed battery float up to life 3~ 5year, FM Fixed-type sealed battery float up to life 8~ 10year, FML Series battery float up to life 10year, FMH Series battery float up to life 10year, GFM Series battery float up to life 15year.

Self-discharge rate is low
The use of special multi-element lead-calcium alloy, the partitions, electrolytes and the production process of strict control of impurities in 20Of the environment, the battery in the 6Months do not have to add electricity to normal use.

Conductive ability
Copper-plated terminal and specially designed to ensure excellent electrical performance.

Ability to adapt to the environment
Available -20~ +50Of the ambient temperature, suitable for desert, highland climate, can be used for special power supply riot area.

Directional
Special diaphragmAGM ) Firmly adsorb the electrolyte so that it does not flow, the battery will not leak either standing or lying to ensure the normal use.

Green pollution-free
Mute, and no pollutants discharged. Battery room without acid-proof anti-corrosion measures, with electronic equipment and other equipment with a room.

Rated voltage

2V

4V

6V

8V

10V

12V

Measured voltage

﹥ 2.1V

﹥ 4.2V

﹥ 6.3V

﹥ 8.4V

﹥ 10.5

﹥ 12.6V

Battery charge:
First, the cycle charge and discharge use mode
1
, If the device is connected to the power supply, charge saturation after leaving the power supply by the battery, in which case you should select the cycle charge and discharge methods.
2
, The maximum voltage supplied by the charging machine during cyclic charging shall be limited: ambient temperature at 25Time, 2VCharge the battery charge voltage is: 2.35-2.45V; 4VThe charging voltage of the battery is: 4.70-4.90V; 6VThe charging voltage of the battery is: 7.05-7.35V; 8V The charging voltage of the battery is: 9.40V-9.80V; 10V The charging voltage of the battery is: 11.75-12.25V; 12V The charging voltage of the battery is: 14.1-14.7VThe maximum charging current is not greater than the rated capacity25%A.
3
, Charge saturation should immediately stop charging, otherwise the battery will be damaged or due to excessive charging will easily lead to the battery drum.
4
, Charge and discharge, the battery can not be inverted.
5
, The life of the cycle depends on the depth of each discharge, the greater the depth of discharge, the battery can be recycled the less the number.
Second, the use of floating mode
1
, If the device is always connected to the power supply, and is in the charging state, but the external power supply is stopped, the battery-powered, in which case should select the floating charge mode.
2
, The battery pack charging voltage of each cell float setting range should be strictly controlled: in the environment 20Time, 2VThe float voltage of the battery is: 2.25-2.30V,The maximum charge current is not greater than the rated capacity value25%A.
3
, Floating charge life is mainly affected by the float voltage and ambient temperature, the higher the float voltage, the battery life is shorter.
Third, the discharge
Discharge terminal voltage is lower than the specified termination voltage or discharge over a number of over-discharge will bring severe damage to the battery, so that battery life is prematurely terminated.

ups Batteries for large items, freight on time charge!