Digital

Digital
 

Product description:



Features: DSP digitally precise control
system;

Multi-stage heating curve programming; (3 segments basic settings can also be customized according to customer needs multi-stage);

The heating time is accurate to 0.1 seconds;

Achieve a variety of operating parameters display;

Rich interface, can be directly incorporated into the RS485, Profibus , CANbus and other industrial bus;

Use PC (PC) software enables engineering machine remote monitoring;

Use the SD card directly recording device operating parameters;

Use status query software, data analysis, fault diagnosis function.

Interactive man-machine interface:

Model / parameters:

model

DIH-25

DIH-40

DIH-60

Export

Rated output power KW

18

25

45

Maximum output power KW

25

40

60

Duty rates

100%

Output power adjustment range

8~100%

5~100%

KHz frequency range

10~55

enter

Input voltage V

3*380

frequency

50Hz

Rated current A

31

45

80

Rated apparent power KVA

21.5

31

45

Maximum apparent power KVA

27.5

45

60

Recommended Insurance A

63

100

cool down

Cooling water minimum flow

10L / min

12L / min

Maximum cooling water inlet temperature

max. 35 ℃

Cooling water pressure min / max

4 / 6bar *

Cooling water -PH value

7.0~9.0

other

Ambient temperature

+5℃~+50℃

Dimensions cm

550 * 250 * 520 (host) 420 * 300 * 480 (extension)

550 * 280 * 580 (host) 450 * 255 * 390 (extension)

510 * 350 * 510 (host)
570 * 330 * 330 (extension)

Weight (kg)

14.5 (host) /13.5 (ext.)

35 (host) / 30 (ext.)

40 (host) / 48 (Extension)