6\12kV heat shrinkable terminations

6\12kV heat shrinkable terminations
 

Product description:


6/12kV heat shrinkable terminations

6/12kV Heat Shrinkable Terminations For Indoor And Outdoor Applications For XLPE And Paper Insulated Power Cables Up To 15 KV
Features:

  • Unique stress control system: High permittivity material
  • ompact design, Few components
  • Simple to install, Minimal waste for disposal
    • Fast, consistent installation means lower installed costs
    • Installation environment: use of torch adds flexibility to cable preparation in any climate
  • High reliability
  • Heat-activated seals ensure maximum protection against moisture ingress
  • ightweight construction requires no additional support
  • UV resistant, non-tracking outer tube for long life, even under adverse conditions.
  • Mechanical robustness
  • Meet: GB/ T 12706 Standard
  1. Insulation tubing
  2. Stress control tubing
  3. Breakout
  4. Trifurcating
  5. Sealing tubing
  6. Phase color tubing
  7. Voil filler

  1. Insulation tubing
  2. Stress control tubing
  3. Breakout
  4. Trifurcating
  5. Sealing tubing
  6. Phase color tubing
  7. Voil filler
  8. Shed
  9. 3-hole shed'

Heat Shrinkable Terminations For XLPE Cables Up To 15kV


  1. Ground braid: Provides shield continuity
  2. Void filler: Moisture sealing, Non-tracking, high voltage filler
    1. Provides a watertight connector seal when combined with heat shrinkable material.
    2. Will not harden or crack.
  3. oll spring: Has a constant-force roll spring, which provides secure grounding without soldering.
  4. Non-tracking, heat shrinkable outer insulation tubing:
    1. Provides excellent UV stability
    2. Withstands polluted environments.
    3. Is proven to withstand severe applications.
  5. Heat shrinkable stress control tubing:
    1. Reduces the electrical stress gradient at the end of the cable shield to safe operating levels.
    2. Shrinks to fit out-of-spec cable.
    3. Provides long-term electrical performance.
  6. Heat shrinkable Rain Skirts:
    1. Increase surface creepage distance.
    2. Easily adapt terminations for outdoor use.
  7. Sealing Insulation tubing
Technical Data
Item No. Property Test condition and Requirement Results
1
AC withstand for 1 min. (dry withstand, for indoor termination) No breakdown and flashover shall occur at 45kV, 1min No breakdown and flashover occurred on the combi. sample at 45kV, 1min
2
AC withstand for 1 min. (wet withstand, for outdoor termination) No breakdown and flashover shall occur at 45kV, 1min No breakdown and flashover occurred on the combi. sample at 45kV, 1min
3
Partial discharge 13kV, ≤20PC 13kV, ≤20PC
4
Load cycle Heating for 5h, cooling for 3h. Conductor's temperature is 95℃, 3 cycles Conductor's temperature is 95℃. Results refer to the following test
5
Impulse voltage withstand 1.2/50us±10times 10 positiVe and 10 negative impulses at 105kV, flashover 1 time is allowed but not including total testing times No breakdown of the combi. sample occurred at 105kV
6
DC voltage withstand negative 15 min. No breakdown and flashover shall occur at 52kV No breakdown and flashover occurred on the combi. sample at 52kV, 15min
7
AC voltage withstand, 4h No breakdown and flashover shall occur at 35kV, 4h No breakdown and flashover occurred on the combi. sample at 35kV, 4h
8
Oil-seal up test
(Only for Paper insulated cables)
Heating for 24h, cooling for 24h. Conductor's temperature is 65℃, oil pressure: 100MPA No leaking, no seeping
Dimensions
Spec. Description
Application
Indoor/ Outdoor
Single Core/ 3-Core
Conductor
Cross Section (mm2)
NSY-15/1x1 6/12kV heat shrinkable terminations for indoor applications for XLPE power cables up to 15 kV
Indoor
Single Core
25~50
NSY-15/1x2
Indoor
Single Core
70~120
NSY-15/1x3
Indoor
Single Core
150~240
NSY-15/1x4
Indoor
Single Core
300~400
NSY-15/3x1
Indoor
3-Core
25~50
NSY-15/3x2
Indoor
3-Core
70~120
NSY-15/3x3
Indoor
3-Core
150~240
NSY-15/3x4
Indoor
3-Core
300~400
WSY-15/1x1 6/12kV heat shrinkable terminations for Outdoor applications for XLPE power cables up to 15 kV
Outdoor
Single Core
25~50
WSY-15/1x2
Outdoor
Single Core
70~120
WSY-15/1x3
Outdoor
Single Core
150~240
WSY-15/1x4
Outdoor
Single Core
300~400
WSY-15/3x1
Outdoor
3-Core
25~50
WSY-15/3x2
Outdoor
3-Core
70~120
WSY-15/3x3
Outdoor
3-Core
150~240
WSY-15/3x4
Outdoor
3-Core
300~400
NSZ-15/1x1 6/12kV heat shrinkable terminations for indoor applications for paper insulated power cables up to 15 kV
Indoor
Single Core
25~50
NSZ-15/1x2
Indoor
Single Core
70~120
NSZ-15/1x3
Indoor
Single Core
150~240
NSZ-15/1x4
Indoor
Single Core
300~400
NSZ-15/3x1
Indoor
3-Core
25~50
NSZ-15/3x2
Indoor
3-Core
70~120
NSZ-15/3x3
Indoor
3-Core
150~240
NSZ-15/3x4
Indoor
3-Core
300~400
WSZ-15/1x1 6/12kV heat shrinkable terminations for Outdoor applications for paper insulated power cables up to 15 kV
Outdoor
Single Core
25~50
WSZ-15/1x2
Outdoor
Single Core
70~120
WSZ-15/1x3
Outdoor
Single Core
150~240
WSZ-15/1x4
Outdoor
Single Core
300~400
WSZ-15/3x1
Outdoor
3-Core
25~50
WSZ-15/3x2
Outdoor
3-Core
70~120
WSZ-15/3x3
Outdoor
3-Core
150~240
WSZ-15/3x4
Outdoor
3-Core
300~400