Portable Paper Moisture Meter MS7200

Portable Paper Moisture Meter MS7200

Product description:

Paper moisture meter MS7200+is used for measuring moisture content of paper tube, carton, paper, cardboard and other paper relevant materials. It applicable of woodwork, paper making , flakeboard, furniture , building, timber traders and other relevant industry.


1.1 It is portable, compact, easy to use and the moisture measurement readings are instant.

1.2 Digital display with back light gives exact and clearly reading although you stay at the somber conditions.

1.3 It will save time and expense by monitoring dryness and helps to prevent deterioration & decay caused by moisture whilst in storage, therefore processing will be more convenient and efficient.

1.4 The moisture meter operates by electrical resistance and has automatic temperature compensation.

1.5 Manual off at any time. Auto power off after 5 minutes from last operation.

1.6 Data hold function. Low battery alert.


Display: 4 digital LCD

Measuring range : 0-95%

Temperature: 0-60°C

Humidity: 5%-85%RH

Resolution: 0.1

Accuracy: ± 0.5%n


Electrical Resistance Method, Automatic temperature


Power supply:

4x1.5 AAA size (UM-4) battery


Main Unit: 140mm*60mm*22mm

Sensor: 175mm*40mm*20mm


175g (not including batteries)

Guarantee: 1 year


4.1 Turn on the power key, the symbol 0'will be showed on display. It will need zeroing if showed other value, please depressZERO key while the probe sensor without touch anything, or zeroing is not efficient. Zeroing can decrease the effect from the temperature and humidity in the air.

4.2 Hold the instrument with your hand, then take off the cover of the sensorandinsert the probes into the materials straightly , the probes are more deeper , the value is more accurate.

4.3 Depress Hold key, the symbol max'will be showed on display, then the max value must be stored on display when measuring process. Depress the Hold key again, this function will be canceled.

4.4Code choice

Depress FUN key and not release until the CD00 is showed on display, through press UP and'DO'key to choose you needed code, then depress FUN key to confirm it.

4.5. Replace batteries

When battery symbol showed on display, it must replace the batteries in time. Slide the batteries cover , put the batteries into the hole correctly.


5.1 Depressing key 3-9 and don't release until AL2 showed on display (it will takes 5 seconds to complete operation) ,thenpress UP key or DO key to choose your suitable value according to your needs, press FUN key again back to the operation state.

5.2 Setting the AL1 just the same ways as AL2'.

5.3 Usually , AL2'must larger than AL1', if the AL2 less than AL1 during setting process, then the instrument will be returned back the factory setting, just to say, AL1=13, AL2=18.

6. Replace batteries

When battery symbol showed on display, it must replace the batteries in time. Slide the batteries cover , put the batteries into the hole correctly.


Please take out the batteries if the instruments without use for a long time.

Put the probe in the air without touch anything when zeroing, or the zeroing is not efficient.





General Material


Hard cardboard, Carton


bundles of waste paper


paper canister, paper tube


High hygroscopic material