Section Hao | Thermal Collection -K3000

Section Hao | Thermal Collection -K3000

Product description:

Section Hao Thermal Collection -K3000

Section Hao Thermal Collection -K3000

product manual:

K3000 Thermal Collection Automation industry personnel in site maintenance and debugging, the special needs of a rapidly detect and diagnose faults carry a variety of instruments, thermal Collection 'is such a good instrument that can verify or simulate pressure transmitter, differential pressure transmitters, vortex flowmeter, thermocouple and thermal resistance, etc., for the field instruments can quickly find the complex power distribution and thermal manual has an output, measure, manuals and 24VDC power distribution function, and four functions can work simultaneously, and is equipped with large capacity rechargeable battery.
Use it with the following characteristics:
&. Small, portable and handheld.
& Rugged, reliable, and hook holes on the back of the support frame suitable for field use.
&. Large display, measurement, output, thermal manual data can be displayed simultaneously.
&. Measure voltage, current, thermocouple, frequency, platinum resistance, copper resistance and general resistance.
& Can be output voltage, current, millivolts, frequency and other signals.
&. 24V DC power distribution output transmitter provides loop power.
& Thermal Engineering Handbook achieve resistance and temperature value, quick mV value and temperature value of peer review, to achieve fast query saturated steam pressure and density, temperature and density.
Technical Parameters
• output signal
• Current: 0 ~ 24mA DC Accuracy: ± 0.05% FS
Resolution: 1μARL ≤400ΩRL * IL≤8V
• Voltage: 0 ~ 6V DC Accuracy: ± 0.05% FS
Resolution: 0.1mVRL ≥10KΩ
• mV: 1 ~ 120mV DC Accuracy: ± 0.05% FS
Resolution: 1μV RL ≥20KΩ
• Frequency: 0 ~ 5000Hz TTL level rectangular wave resolution: 0.1Hz
Output range

1.0000 ~ 99.999 Hz
0.02 Hz

100.00 ~ 999.99 Hz
0.4 Hz

1000.0 ~ 1999.9 Hz
3 Hz

2000.0 ~ 3000.0 Hz
5 Hz

3000.0 ~ 5000.0 Hz
15 Hz

• DC: 24VIL (30mA Accuracy: ± 2%

• measurement signal
• Current: 0 ~ 35mA DC Accuracy: ± 0.05% FS
• Voltage: 0 ~ 5V DC accuracy: ± 0.05% FS
0 ~ 35V DC accuracy: ± 0.1% FS
• mV: 1.10 ~ 100.00mV DC Accuracy: ± 0.05% FS
• Resistance: 0.0 ~ 1200.0Ω Accuracy: ± 0.05% FS
• Frequency: 0.0 ~ 5000.0Hz (square wave) Accuracy: ± 0.2Hz
• Thermal Engineering Handbook (the implementation of international ITS-90)
• Achieve resistance and temperature values ​​peer review (of Pt10 and Pt100 thermal resistance).
• Achieve millivolts and temperature value peer review (of S, K, B, R, J, E, T, N type thermocouple).
. • achieve saturated steam pressure (P) Charles density (ρ), temperature (T) to check the density (ρ) of Enquiry range: absolute pressure range: 0.1MPa ~ 16Mpa; temperature range: 100 ℃ ~ 350 ℃.
Power supply:
The instrument is equipped with a high-capacity rechargeable battery, the capacity is 10800mAh, external power supply DC12V, 1.0A charging is eight hours per charge, the red light on the book panel charging, the green light after charging is completed. At the same time charging, Collection still work. once charging after work 8 to 16 hours, its duration and use status.
Ambient temperature:
Working temperature: -10 ~ 50 ℃;
Storage temperature: -20 ~ 70 ℃
Weight 0.7kg