AI PID regulator

AI PID regulator
 

Product description:

AI PID regulator

SD-5300 series of artificial intelligence PID regulator









Outline
SD-5300 series of artificial intelligence, fuzzy regulator PID control algorithm uses the differential forward with external given and valve control functions. Can be used with various types of sensors, transmitters used in conjunction to achieve the temperature, pressure, level, capacity measured physical quantity speed display, and with a variety of actuators and solenoid electrical heating equipment, electric valve PID regulation and control, alarm control, data acquisition and other functions.
Dual LED digital display, and with a light beam simulation indicator (0 to 100%).
With 36 kinds of signal input function can be arbitrarily selected input signal type; 0.2% level measurement accuracy.
With 'upper and lower alarm', deviation alarm ', LBA alarm', flashing alarm 'and other alarm function, with LED warning lamp.
You can take all the way to PID control outputs and one analog transmit output, with current, voltage, SSR drive, single / three-phase thyristor zero trigger, relay contacts selectable output control mode.
With PID parameters self-tuning function, the control output manual / automatic switching function without disturbance, accurate control and without overshoot.
Supports RS485, RS232 serial interface, using the standard MODBUS RTU communication protocol.
The instrument can be with RS232C print function, with manual print, regular print, alarm printing.
With DC24V feed output for on-site transmitter power distribution.
Between each other using optical isolation technology input, output, power, communications.
With a variety of dimensions and styles to choose from.
Parameter setting password lock, parameter setting off permanently preserved, with parameters to restore the factory setting function.

Remarks:
1. Please select the function selection according to wiring diagram, due to the small size of the instrument with less terminals not fully functional, some functions on the same set of terminals can only choose one feature.
2, size of the F-type instrument without RS232C printing interface, size of H-type instruments can only do single control.
3, size of D, E type of instrument, terminals 25 to 36 with alarm function if the relay contact capacity AC125V / 0.5A, DC24V / 0.5
A, Size of H-meter relay capacity, like other sizes of meter relay contact capacity AC220V / 2A, DC24V / 2A.
4, when the meter to control the output function K5 (forward and reverse output), alarm output can only choose 2 limit alarm.
5, when the Model SD-5310/5320 control output select K1 refers to a single relay contact output; when the Model SD-5330 control output select means K1 relay contact output reversing.
6, when writing the model must be complete, there is no election to the function item can not be omitted, we must use 'X' to make up.
Example 1: SD-5310A-14 / X-0/0/2 / X / X-A (single control)
Example 2: SD-5320A-14/27-K1 / 0/2 / D1 / XA (external reference control)
Example 3: SD-5330A-14 / 27-0 / 0/2 / Y1 / XA (valve position feedback control)
Example 4: SD-5330A-14/27-K1 / 0/2 / D1 / XA (reversing control valve position feedback input output)
Example 5: SD-5330A-14 / X-K1 / X / 2 / X / XA (non-reversing control valve position feedback input output)