Supply Ricoeur Albert Instrument FT-102 Hall flow meter / Bulk Density Tester

Supply Ricoeur Albert Instrument FT-102 Hall flow meter / Bulk Density Tester
 

Product description:

Brand: Ricoeur Albert Instrument Model: 102
Detailed description:
Repeatability error: 1 Samples can be measured state: Powder Powder
Custom processing: Measuring range: FT-102 Hall flow meter / Bulk Density Tester (stainless steel material)
Type: Density Tester Scope: FT-102 Hall flow meter / Bulk Density Tester (stainless steel material)
Dimensions: 3 (mm) Repeatability error:
Samples can be measured state: Custom processing:
Measuring range: Types of:
Scope: Dimensions:

FT-102 Hall flow meter flow and bulk density measuring device The instrument is replaced GB1479-84, GB1482-84 standard specification production with the design, production according to GB 1482-2010-T metal powder flowability measurement standard funnel (Hall flow meter). Its detection methods and results and international common detection method has versatility. This product is also applicable to similar powder powder flowability and bulk density measurements.

This device is intended for determination of metal powder flowability using a standard funnel in. Where can freely flow through the aperture to 2.5mm Standard funnel powder, can use this device.

Test Buju

1 Weigh 50g A sample, accurate to ± 0.1g .

2 Hand to block the hole at the bottom of the funnel, the weighed 50g Sample poured into the funnel, note the lower end of the powder must be filled funnel entire hole.

3 Moment when being opened holes and start timing funnel, powder funnel flow once completed, immediately stop the clock.

4 Record funnel all the time required to complete the sample stream, and repeated three times, and the arithmetic mean, the time recorded to the nearest 0.1s .

Note: If and when the hole being opened, the powder does not flow, you can tap on the funnel look to the powder begins to flow. However, even if this is done, the powder is still not out of or during the measurement of powder to stop the flow, you should consider this powder having no flowability.

Test Results

The arithmetic average of the three sample results are multiplied by the correction coefficient funnel to s / 50g reported data, report data is accurate to 0.5s.

Please fill in the test report: The test report shall include the following:

a. Necessary to explain the identification of the sample;

b. The handling of the sample, if the powder is dried, the drying process should be indicated;

c. If the flow of powder is caused due to the beat funnel should be specified;

d. Calculation results;

e. It may affect the outcome of any case.

FT-102 Hall flow meter / Bulk Density Tester It is based on national standards GB provisions of the design and production of 1482-84.

This device is intended for determination of metal powder flowability using a standard funnel in.

Where can freely flow through the aperture of 2.5mm standard funnel powder, can use this device.

FT-102 Hall flow meter / Bulk Density Tester Principle

Metal powder flowability to 50g metal powder to flow through a standard funnel predetermined aperture required to represent.

FT-102 Hall flow meter / Bulk Density Tester Technical Requirements

2.1 funnel (hole diameter 2.5mm)

Funnel made of stainless steel, and has a sufficient thickness and hardness to prevent deformation and excessive wear.

2.2 bracket, base and receiving cylinder

Bracket for fixing the funnel. Base for mounting bracket and receiver Graduate Please adjust the level, stable and vibration free. Stand height adjustment and fixed with the supplied wrench, funnel attached to the bracket. Reception Graduate (Stainless steel plate) is placed on the base, to collect the powder.

2.3 Balances (user-supplied)

The largest weighing 100g; precision 0.05g.

2.4 Stopwatch

Measurement time can be accurate to 0.01s.

2.5 cups

The device is equipped with a volume of 25ml stainless steel measuring cup. Users can complete the determination of metal powder bulk density (Funnel method) reference to the provisions of the national standard GB 1479-84.

FT-102 Hall flow meter / Bulk Density Tester Basic configuration: The stand: 1 set; Funnel: Stainless steel (Φ2.5mm, Φ5.0mm) each one; cup; stainless steel (Φ31mm, 25ml) 1 只; stopwatch 1; overflow trays stainless steel 1; brush 1; ruler 15cm1 the manual; warranty card; certificate.

Ricoeur instrument tips, as well as associated products FT-102A vibration funnel bulk density tester, FT-100A tap density tester; FT-101 Scott capacity meter bulk density tester, FT-102 Hall flow meter / Bulk Density Tester - stainless steel ; FL4-1 Hall flow meter / powder flowability tester - brass

Ricoeur Instruments Companies' quality-oriented 'service first' operating principles. Meet the needs of our customers. Companies in the 'science and technology, creativity, innovation, progressive' entrepreneurial spirit, the introduction of advanced production equipment and manufacturing process, through continuous technology to improve and perfect the management, strive to provide customers the best quality products and service!

FT-102 Hall flow meter / Bulk Density Tester Operation video link:

http: //v.youku.com/ v_show / id_XMzc3NDYyODg0 html.









FT-102 Hall flow meter flow and bulk density measuring device The instrument is replaced GB1479-84, GB1482-84 standard specification production with the design, production according to GB 1482-2010-T metal powder flowability measurement standard funnel (Hall flow meter). Its detection methods and results and international common detection method has versatility. This product is also applicable to similar powder powder flowability and bulk density measurements.

This device is intended for determination of metal powder flowability using a standard funnel in. Where can freely flow through the aperture to 2.5mm Standard funnel powder, can use this device.

Test Buju

1 Weigh 50g A sample, accurate to ± 0.1g .

2 Hand to block the hole at the bottom of the funnel, the weighed 50g Sample poured into the funnel, note the lower end of the powder must be filled funnel entire hole.

3 Moment when being opened holes and start timing funnel, powder funnel flow once completed, immediately stop the clock.

4 Record funnel all the time required to complete the sample stream, and repeated three times, and the arithmetic mean, the time recorded to the nearest 0.1s .

Note: If and when the hole being opened, the powder does not flow, you can tap on the funnel look to the powder begins to flow. However, even if this is done, the powder is still not out of or during the measurement of powder to stop the flow, you should consider this powder having no flowability.

Test Results

The arithmetic average of the three sample results are multiplied by the correction coefficient funnel to s / 50g reported data, report data is accurate to 0.5s.

Please fill in the test report: The test report shall include the following:

a. Necessary to explain the identification of the sample;

b. The handling of the sample, if the powder is dried, the drying process should be indicated;

c. If the flow of powder is caused due to the beat funnel should be specified;

d. Calculation results;

e. It may affect the outcome of any case.

FT-102 Hall flow meter / Bulk Density Tester It is based on national standards GB provisions of the design and production of 1482-84.

This device is intended for determination of metal powder flowability using a standard funnel in.

Where can freely flow through the aperture of 2.5mm standard funnel powder, can use this device.

FT-102 Hall flow meter / Bulk Density Tester Principle

Metal powder flowability to 50g metal powder to flow through a standard funnel predetermined aperture required to represent.

FT-102 Hall flow meter / Bulk Density Tester Technical Requirements

2.1 funnel (hole diameter 2.5mm)

Funnel made of stainless steel, and has a sufficient thickness and hardness to prevent deformation and excessive wear.

2.2 bracket, base and receiving cylinder

Bracket for fixing the funnel. Base for mounting bracket and receiver Graduate Please adjust the level, stable and vibration free. Stand height adjustment and fixed with the supplied wrench, funnel attached to the bracket. Reception Graduate (Stainless steel plate) is placed on the base, to collect the powder.

2.3 Balances (user-supplied)

The largest weighing 100g; precision 0.05g.

2.4 Stopwatch

Measurement time can be accurate to 0.01s.

2.5 cups

The device is equipped with a volume of 25ml stainless steel measuring cup. Users can complete the determination of metal powder bulk density (Funnel method) reference to the provisions of the national standard GB 1479-84.

FT-102 Hall flow meter / Bulk Density Tester Basic configuration: The stand: 1 set; Funnel: Stainless steel (Φ2.5mm, Φ5.0mm) each one; cup; stainless steel (Φ31mm, 25ml) 1 只; stopwatch 1; overflow trays stainless steel 1; brush 1; ruler 15cm1 the manual; warranty card; certificate.

Ricoeur instrument tips, as well as associated products FT-102A vibration funnel bulk density tester, FT-100A tap density tester; FT-101 Scott capacity meter bulk density tester, FT-102 Hall flow meter / Bulk Density Tester - stainless steel ; FL4-1 Hall flow meter / powder flowability tester - brass

Ricoeur Instruments Companies' quality-oriented 'service first' operating principles. Meet the needs of our customers. Companies in the 'science and technology, creativity, innovation, progressive' entrepreneurial spirit, the introduction of advanced production equipment and manufacturing process, through continuous technology to improve and perfect the management, strive to provide customers the best quality products and service!

FT-102 Hall flow meter / Bulk Density Tester Operation video link:

http: //v.youku.com/ v_show / id_XMzc3NDYyODg0 html.