FZS4-4 tap density tester, Ricoeur equipment manufacturing heap densitometer

FZS4-4 tap density tester, Ricoeur equipment manufacturing heap densitometer
 

Product description:

  • Types of: other
Detailed description:
Weight: 21 (kg) The scope of products: tap density tester
Power: 1 Operating voltage: 1 (V)
Custom processing: Dimensions: 1
Measuring range: FZS4-4 tap density tester, Ricoeur equipment manufacturing heap densitometer weight:
Products Scope: power supply:
Operating Voltage: Custom processing:
Dimensions: Measuring range:

FZS4-4 tap density tester

The new tap density tester / Zhejiang powder density test / tap density measurement provided by Ricoeur instrument price / Ningbo sales tap density tester / metal powder tap density tester / nonmetal tap densitometer price / tap Density manufacturers / microcomputer-based tap density tester

FZS4-4 type tap density tester

FT-100 tap density tester / Powder Density Tester

FT-100 Powder Density Tester Is based on GB / T 5162-2006 / ISO3953: 1993 (metal powder tap density measurement), and with reference to the United States Pharmacopoeia independent research and manufacture of the powder density testing equipment, with independent intellectual property rights instrument covers the national standard GB / T 5162-. 2006 / ISO3953: 1993 in the indicators.

FT-100 Powder Density Tester By a variable speed motor, vibration components, micro and mini printers and other components. And the instrument with a compact, solid, simple operation.

FT-100 Powder Density Tester Technical Specifications:

  1. Sample weight: ≤500.00 g;
  2. Sample volume: ≤250.00 milliliter;
  3. Single frequency vibration: 0 ~ 99999 Views (when set to 0 Times when the result is output as 'bulk density') ;
  4. Allow the motor torque: 0.86 N.m;
  5. Vibration frequency: 0 to 300 rev / min (adjustable);
  6. Vibration amplitude: maximum 14mm, 1-14mm adjustable integer;
  7. Repeatability error: ≤1%;
  8. Accuracy error: ≤1%;
  9. Input Power: AC 220V (50Hz / 60Hz), 40W.

FT-100 Powder density tester objects
Various metal powders: such as aluminum powder, zirconium powder, nickel powder, tungsten powder, tin powder, zinc powder, molybdenum powder, magnesium powder, copper powder and other precious metals, an alloy powder or metal oxide powder and the like.
Non-metallic powder: such as talc, kaolin, calcium carbonate, coal, phosphor, brucite, calcite, wollastonite, tourmaline, diamond, barite, fluorite, zeolite, boron carbide, clay, graphite, quartz, gypsum, bentonite, diatomaceous earth, zirconium silicate, alumina, mica, clay, titanium dioxide and the like.
Other powders: such as soil, dyes, pharmaceuticals, pesticides, abrasives, paints, food additives, catalysts, cement, sand and other rivers.

Note: Specific parameters, please keep in touch with us, as well as related products.

FZS4-4 type tap density tester

The instrument system according to international standard ISO3953 requirements of production, GB T 5162-2006 (determination of metal powder tap density) / satisfied, and with reference to the United States Pharmacopoeia independent research and manufacture of the powder density test instruments for measuring tap density of the powder The powder through the tap, its density increases the percentage is a comprehensive reflection of the powder variety of performance. The instrument is adopted by an eccentric rotation causes directional slider up and down the slide, percussion drill seat, the inner cylinder powder gradually tap means, mainly used for the determination of various shapes powder tap density, non-metallic powder also can learn to use.

The main technical parameters

Vibration stroke tap apparatus 3 ± 0.1MM

Vibration frequency 250 ± 15 beats per minute

Glass cylinder volume is 100 ± 1.0ml, graduated some high 175 ± 10mm. Glass cylinder volume of 25 ± 0.5ml scale section of a high 135 ± 7mm. 100ml graduated cylinder volume between the smallest scale is 1ml, measurement accuracy of ± 0.5cm ; cylinder between 25cm minimum scale volume of 0.2cm, measurement accuracy of ± 0.1cm

FZS4-4 tap density tester

FZS4-4 tap density tester

FZS4-4 tap density tester