Supply Ricoeur instrument dust repose angle measurement, angle of repose instrument, repose angle device

Supply Ricoeur instrument dust repose angle measurement, angle of repose instrument, repose angle device
 

Product description:

Brand: Ricoeur Instrument Model: 103b
  • Types of: other
Detailed description:

FT-103B dust repose angle measurement, angle of repose instrument (injection limited underside of law)

FT-103B dust repose angle measurement standards

GBT 16913-2008 dust dust physical test methods repose angle measurement (injection limited underside of law)

FT-103B dust repose angle measurement principle:

Sufficient overflowing trays dust injected from the mouth of the funnel to the horizontal feed tray; measure dust accumulation and the bottom horizontal bevel sandwiched acute angle, that dust angle of repose.

FT-103B dust repose angle measurement test requirements and procedures

Angle of repose measuring device dust injection limited underside of law, should be placed on the test stand; funnel plugged with a stopper spout would like dust sample loading cylinder filled with a blade Calibrating poured into the funnel back out of the stopper. , so that dust from the funnel orifice outflow; for bad fluidity dust, dust can be used to make knitting stir continuously living on trays until all the dust out of the rotation protractor to measure out on trays dust cone bus and the horizontal plane. clip acute angle, that angle of repose, and the records shall be continuously measured 3 times to 5 times, find the arithmetic mean and standard deviation a A

FT-103B dust repose angle measurement Technical parameters:

1, the funnel taper 60 ° ± 0.5 °;

2, the outflow diameter 5mm, funnel and the lower center tray center should be on a vertical line;

3, along with the disk bottom spout distance 80mm 2 mm, protractor 7.5cm ~ 10 cm;

4, material disc diameter 80 mm, volume 100 ml graduated cylinder;

5, straight blade-like dust, knitting;

Ricoeur instrument prompts you: You may also use the following package of products: FT-103B dust repose angle measurement; FT-103 bulk density meter repose; FT-104B repose angle measurement

FT-103B dust repose angle measurement Instructions
First, the scope
The products for production, management, and use of laboratory determination of physical properties of dust use.
This instrument is suitable for testing the angle of repose of dust.
Second, the applicable standard requirements:

Determination of GB / T16913-2008 dust angle of repose for the performance of

Third, the technical requirements

First, the standard requirements: GBT 16913-2008 dust dust physical test methods repose angle measurement (injection limited underside of law)

Sufficient overflowing trays dust injected from the mouth of the funnel to the horizontal feed tray; measure dust accumulation and the bottom horizontal bevel sandwiched acute angle, that dust angle of repose.

Third, the test requirements and procedures: the angle of repose of dust injection means defining a bottom surface measuring method, should be placed on the test stand; funnel plugged with a stopper spout would like dust sample loading cylinder filled with a blade Calibrating after Pour stopper out of the funnel, so that dust from the funnel orifice outflow; for bad fluidity dust, dust can make knitting stir continuously living on trays until all the dust out of the rotation protractor to measure out on trays. dust cone bus sandwiched acute angle with the horizontal plane, that angle of repose, and the records shall be continuously measured 3 times to 5 times, find the arithmetic mean and standard deviation a A

Instructions
1, horizontal good analyzer.

2, will have a good pre-treatment sample using this meter standard 100ml cup installed.

3, the use of jamming bars, or other tools to block the leak funnel 6mm

4, to the sample, take away jamming bars or other tools

5, powder 80mm diameter vertical fall by material platform above, to form a taper.

6, using a protractor to measure the angle formed tapered concrete

Albert Instrument Co., Ltd. Ningbo Jiangbei Ricoeur

(Referred to Ricoeur instrument English: Ningbo Rlco instrument Co., LTD)

RICO Ricoeur began in 1999, the Department of Ricoeur instrument enterprise systems; Ricoeur instrument enterprise system is mainly engaged in analytical instruments, precision testing equipment and advanced detection equipment research and development, production, sales and after-sales service for the integration of the Industrial Company.

RICO Ricoeur which owns the trademark, the products meet the requirements of international standards of IEC, CCC, UL, CSA, VDE, JIS, KS, SEV, BSI, HD, KEMA, SSA and the like.

Quality-oriented company, the operating principle of service first. Meet the needs of our customers. Companies in the technology, creativity, innovation, progressive spirit of enterprise, the introduction of advanced production equipment and manufacturing process, through continuous technological improvement and management perfection, and strive to provide customers the best quality products and service!

The company's business scope involving chemical, oil, polymer materials, powder metallurgy, powder powder, pharmaceuticals, batteries, plastics, construction materials, wire (Harness) processing, and other related industries.

Provide the most complete product testing solutions and technical advice for the production enterprises, research institutes and universities

FT-103 Natural Accumulation bulk density meter , Dust accumulation densitometer

FT-103 Natural bulk density meter stacking performance standards

It is based on national standards GB / T 16913.3-1997 provisions of design and production. The device is suitable for the determination of bulk density of dust.

Ricoeur instrument company also produces the following series : Powder flowability tester / Bulk Density Tester / Hall flow meter / tap density tester / Scott capacity meter bulk density tester / bulk density meter / aluminum powder Bulk Density Tester / angle of repose Tester / angle of repose tester / apparent density analyzer / tap density tester / aluminum fluoride (Alumina) Mobility analyzer

FT-103 Natural Accumulation bulk density meter Please refer to the sample collection GB / T 16913.1-1997 dust Physics Experiment Part 1: Dust samples collected in the relevant regulations.

FT-103 Natural Accumulation bulk density meter Principle: Dust from the funnel mouth full of free fall at a certain height measuring cup; mass per unit volume of dust inside the cup measured bulk state, that dust bulk density.

FT-103 Natural Accumulation bulk density meter Structure: funnel (flow outlet diameter 12.7mm)

Funnel made of stainless steel, which funnel taper of 60 ° ± 0.5

Ricoeur instrument prompts you: You may also use the following package of products : FT-103B dust repose angle measurement; FT-103 - Natural bulk bulk density meter; FT-104B repose angle measurement

Dust sampling experiments should be consistent GB / T 16913.1-1997 The provisions of Registration dust sampling conditions.

3.2 Dust samples in 105 ℃ dried 4 Hours after placing indoor natural cooling through 80 Mesh sieve to debris, ready determination.

Note: For less 105 Chemical reaction occurs when ℃ or melting, sublimation of dust, the drying temperature should be reduced accordingly.

3.3 The measuring device to adjust the level.

3.4 Stick stuffed with jam funnel spout. Measure 120ml The sample is poured into the funnel.

3.5 Pull out the stopper so that dust naturally fall to the lower cylinder in until after all the dust out of the funnel with a scraper to scrape the dust accumulated in the upper part of the cylinder.

3.6 The cylinder is equipped with dust sample was weighed on the balance weight.

3.7 Dust above procedure was repeated three times the bulk density is calculated according to the formula:

Where: ρ0 - Dust bulk density. g / cm3 ;

m1 , m2 , m3 - Measuring the quality of secondary dust were weighed. g ;

V - Cylinder volume. 100ml ;

continuous 3 Quality dust determinations resulting difference between maximum and minimum values ​​should be less than 1g Otherwise, for the first 4 (Article 5 First 6 ) Determinations, until the difference between the maximum value and the minimum value is less than 1g , Take to meet the requirements of 3 Measurements average as measurement results.