AND48 series of communications power inverter

AND48 series of communications power inverter
 

Product description:

Input voltage: 1 (V) Waveform distortion: 1 (%) Frequency regulation of: 1 (%)
Output voltage: 1 (V) Load regulation: 1 (%) Circuit mode: SPWM switching
Load Type: Mixed loads Custom processing: Efficiency: 1 (%)
Applications: Computer equipment Type: Inverter Type: AND
Output frequency: 1 (Hz) Brand: ACS Product Certification: CCC
Control mode: Pulse width modulation type Input Frequency: 1 (Hz)

(Introduction)

西安杰瑞达 Instrument Co., Ltd. is a manufacturer with international authority recognized ISO9001 international quality standard management system. Specialized in producing power equipment. Inverter device is a DC electrical energy into uninterrupted, clean AC power The conversion means to provide computers and other electrical equipment can be used continuous AC power, preparedness and unstable mains power. can also prevent distortion of public communication of all kinds, such as the supply voltage drops, surge, spikes and Radio frequency interference.

(Features)

• Fully isolated inverter technology, no noise pure sinusoidal AC output voltage;

• The inverter unit with microprocessor control; SPWM sinusoidal pulse width modulation technique; waveform pure;

• unique dynamic current loop control technology to ensure reliable operation of the inverter;

• overload capacity, can withstand computer load power surge;

• High-power static bypass switch; by the bypass when the overload; switching time is short;

• With input over; undervoltage; output over; undervoltage; over-temperature; short circuit protection;

• The inverter front panel LED display, status at a glance;

• Multiple lightning protection scheme option;

(Main Specifications)

Model (AND48-)

1005

1010

1020

1030

1050

1080

1100

Rated Capacity

500VA

1KVA

2KVA

3KVA

5KVA

8KVA

10KVA

Operation mode

Pure Inverter

DC input

Rated voltage (V)

48VDC

Voltage range (V)

40 ~ 55 VDC

Current (A)

10.4

20.8

41.6

62.5

104.2

166.7

208.3

AC bypass input

Input voltage range (VAC)

220±15%

Enter the maximum current (A)

2.3

4.5

9

13.6

23

36

45

Switching time (mS)

4ms

AC output

Rated power (KW)

0.4

0.8

1.6

2.4

4

6.4

8

Rated Current (A)

2.3

4.5

9

13.6

23

36

45

Power factor (PF)

0.8

Output voltage accuracy

AC220 V ± 1%

Waveform

Sine wave

Output frequency accuracy (Hz)

50HZ ± 0.1%

Waveform distortion (THD)

≤3%

Changes in an instant

± 5% (0 ~ 100% load)

Crest factor (CF)

3: 1

Inverter efficiency (%)

90 (80% resistive load)

92 (80% resistive load)

Insurance

Protect

Output overload protection

150%, maintained 30S

Output short circuit protection

Shutdown protection, artificial restoration

DC low voltage protection

Inverter shutdown, automatic recovery

Over-temperature protection system

85 ℃ shutdown protection, 75 ℃ automatically restored

Enter the reverse protection

no work

working environment

Noise (1 meter)

≤40db

Dielectric strength

Input to output 3000VAC, 1 分钟

Working temperature

-10~45℃

Relative humidity

20% to 90% non-condensing

Altitude (m)

≤1000

cooling method

Forced air