15KVA AC-DC power supply voltage frequency stabilization

15KVA AC-DC power supply voltage frequency stabilization
 

Product description:

Input voltage: 1 (V) Waveform distortion: 1 (%) Frequency regulation of: 1 (%)
Output voltage: 1 (V) Load regulation: 1 (%) Circuit mode: SPWM switching
Load type: inductive load Custom processing: Efficiency: 1 (%)
Applications: Electronics Manufacturing Type: sine wave power inverter Model: AF50
Output frequency: 1 (Hz) Brand: ACS Product Certification: CCC
Control mode: current- Input Frequency: 1 (Hz)

15KVA AC-DC power supply voltage frequency stabilization Features:

The power supply frequency stabilization power supply adopt advanced sinusoidal pulse width modulation (SPWM) IGBT high frequency inverter technology, internal for the AC - DC - AC structure, the elimination of grid disturbance, the output waveform is pure, with voltage regulation, frequency stabilization range, high precision, light weight, small size, frequency stabilization power output with isolation transformer, etc., can constitute high quality uninterrupted power supply system and generator good match.
Frequency stabilization power supply
The main technical parameters:
1, the input voltage: 130 ~ 280V
2, frequency stabilization power input frequency: 35 ~ 70Hz
3, the output voltage: 220V ± 0.5%
4, frequency stabilization power output frequency: 50Hz ± 0.01%
5, waveform distortion: (1%
6, the isolation transformer output, safe and reliable
7, frequency stabilization power supply with output overvoltage; overcurrent; overload; overheating; short circuit protection and automatic alarm
8, more than 90% efficiency for wide loads, for inductive, capacitive, resistive, and any mixed load.
9, fast dynamic response, 0-100% load change, the steady-state response time (0.1S
10, input and output voltage and frequency, please note when ordering.

Frequency stabilization power supply Applications:
Railway; aviation; navigation system
Sophisticated testing medical electronic equipment
Imports of electronic and electrical equipment supply
Exports of electronic and electrical product testing
CNC machine tools; light textiles; automated production lines
Consisting of a generator plant supporting high performance uninterruptible power supply system

Product Specifications (special specifications according to customer requirements)

Voltage
Electric current

0-30V

0-50V

0-60V

0-100V

0-150V

0-300V

0-400V

0-600V

5A

RS-
1005K

RS-
1505K

RS-
3005K

RS-
4005K

RS-
6005K

10A

RS-
5010K

RS-
6010K

RS-
10010K

RS-
15010K

RS-
30010K

RS-
40010K

RS-
60010K

20A

RS-
3020K

RS-
5020K

RS-
6020K

RS-
10020K

RS-
15020K

RS-
30020K

RS-
40020K

30A

RS-
3030K

RS-
5030K

RS-
6030K

RS-
10030K

RS-
15030K

RS-
30030K

50A

RS-
3050K

RS-
5050K

RS-
6050K

RS-
10050K

100A

RS-
30100K

RS-
50100K

RS-
60100K

200A

RS-
30200K

RS-
50200K

300A

RS-
30300K

※ performance indicators (* optional feature)

1, CV (constant voltage) Operating:
Source effect: 0.2% + 20mV
Load effect: 0.2% + 20mV
Periodic and random offset voltage (PARD): 0.3% + 30mV (rms)
2, when the operating voltage CV drift 1X10-3 + 10mV / 7 小时 (20 ± 20C)
3, CV can use the remote control (with an external sampling function) *
4, remote control potentiometer output voltage, the master resistance 0 to 4.7 Kohm, charged voltage of 0 ~ Rating *
5; a voltage output voltage remote control; the master voltage of 0 to 5 volts; controlled voltage 0 ~ Rating *
6, remote control potentiometer output current master resistance 0 to 4.7 Kohm, accused current 0 ~ Rating *
7; a remote control voltage output current; master voltage from 0 to 5 volts; charged current 0 ~ Rating *
8, overvoltage protection voltage value within 0 to + 2V adjustable ratings, when an overvoltage output, the output power is automatically shut down and an alarm is locked.
9, the meter accuracy: 1% ± 2 words.
10, warm-up time: 15 minutes, but when measuring drift of 1 hour.
11, use of the environment: according to the national standard GB6587-86 (master environmental testing electronic measuring instruments) Table 1. Group II requirements.
12, 8 hours continuous operation at full load (at 40 ℃ environment of long-term use).
13, the power supply voltage 220 V ± 10%
14, 50 ± 10 Hz power frequency