AND220 series power inverter

AND220 series power inverter
 

Product description:

Input voltage: 1 (v) Waveform distortion: 1 (%) Frequency voltage regulator: 1 (%)
Output voltage: 1 (v) Load voltage: 1 (%) Circuit mode: SPWM switch
Type of load: resistive load Customized processing: Yes Efficiency: 1 (%)
Applications: computer equipment Type: single phase inverter power Model: AND220
Output frequency: 1 (Hz) Brand: ACS Control mode: pulse-width modulation
Input frequency: 1 (Hz)

(Product brief)

The power inverter is a mains and battery power into a continuous, clean AC power transducers, to provide computers and other power supply equipment of continuous AC power can be used to guard against instability and sudden power off of the mains. Also can prevent public power of various distortion, as power voltage declined, waves Chung voltage, pointed peak power and the broadcast frequency interference, the series inverse variable power designed for power plant, substation design, widely application Yu power system communications, monitoring, following electric protection and accident lighting, also can for Exchange lubricants pump, Exchange wind machine, pump, provides not continuous power and widely application Yu aviation space, financial system, Office Automation control, medical health, military research, all field.
(Main features)

1; Circuit compact; High efficiency; Earthquake preparedness;

2; Total isolated DC inverter technology; AC noise-free pure sine-wave output voltage;

3; Wide input voltage range; High voltage stabilizing precision; Environmental adaptability;

4; Inverter unit with microprocessor control; Sine pulse width modulation SPWM technique; Wave pure;

5, unique dynamic current control technology to ensure reliable operation of the inverter;

6; Overload capability; Can withstand the load power surge hit the computer;

7; Mitsubishi IGBT; Mitsubishi driver module; Ruby; Suzuki import filter capacitors;

8, with input over/under voltage, output over voltage, over temperature, short circuit protection. Protection, long service life

9; High-power static bypass switch; Can be converted automatically bypass the power supply overload; Switching time is short;

(Standard)

(GB7260-87 uninterruptible power supply equipment) (Q/01AK001-2005 program-controlled frequency power supply) (GJB181A-2003 powered aircraft characteristics) (GJB572-88 aircraft ground power supply characteristics and General requirements)
(Technical data)

Model

AND220-1010

AND220-1020

AND220-1030

AND220-1050

AND220-1100

AND220-1200

AND220-1300

AND220-1500

DC input

Input rated voltage

220VDC

Input rated current

5A

10A

15.2A

25A

49A

99A

148A

247A

Input DC power supply range

180-300VDC

AC bypass input

Permissible input voltage range

220V±15%VAC

Input rated current

4.5A

9A

13.6A

22.7A

45A

91A

136A

227A

Bypass time

≤4ms

AC output

Rated capacity

1KVA

2KVA

3KVA

5KVA

10KVA

20KVA

30KVA

50KVA

Rated output power

0.8KW

1.6KW

2.4KW

4KW

8KW

16KW

24KW

40KW

Rated output voltage and frequency

220VAC, 50HZ

Rated output current

4.5A

9A

13.6A

22.7A

45A

91A

136A

227A

Output voltage accuracy

220V±3%

Output frequency accuracy

50HZ±0.05

Waveform distortion (linear load)

THD≤±2%

Dynamic response (load 0-100%)

5%

Power factor (PF)

0.8

Overload capacity

150%, 10s

Peak factor (CF)

3: 1

Inverter efficiency

90%

92%

Communication interface (optional)

RS232/485

Work environment

Dielectric strength (input and output)

1500VAC 1 minute

Noise (1 m)

≤50dB

The use of ambient temperature

-10~50℃

Humidity

0-90% (non-condensing)

Use elevation

≤2000

Mechanical dimensions

Vertical width * depth * height (mm)

190*320*320

240*480*405

550*600*980

600*550*1400

1000*800*2260

Rack width * depth * height (mm)

482*405*133

482*405*178

482*420*222

No

Reference weight (Kg)

18

30

40

60

150

260

360

700

Protection function

Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, and overtemperature protection.