AND48 telecommunications power inverter

AND48 telecommunications power inverter
 

Product description:

Input voltage: 0 (V) Waveform distortion: 0 (%) Frequency regulation: 0 (%)
Output voltage: 0 (V) Load regulation: 0 (%) Circuit mode: SPWM switching
Load Type: Rectifier load Custom processing: Efficiency: 0 (%)
Applications: Electronics Manufacturing Type: Single-phase inverter power supply Model: AND48
Output frequency: 0 (Hz) Brand: ACSOON Product Certification: CCC
Control mode: Pulse width modulation type Input Frequency: 0 (Hz)

AND48 telecommunications power inverter (48V input)

AND48 telecommunications power inverter (48V input) Description:

AND48 telecommunications power inverter (48V input) is the new generation of power, the series power supply designed for telecommunications systems and all of the power supply interference sensitive, needs a stable, reliable, clean AC uninterruptible power supply system design. This series of power supply with high performance Microprocessor-controlled, high-frequency IGBT inverter technology, built-in AC bypass design, with load adaptability, high reliability, low distortion, easy operation and maintenance and so on.

AND48 telecommunications power inverter (48V input) features:

⑴; using SPWM technology; pure sine wave output

⑵; advanced anti-jamming technology; excellent EMI / EMC Index

⑶; boot soft-start circuit; improve product reliability

⑷; static electronic bypass switch; uninterruptible AC bypass switch

⑸; overvoltage; undervoltage; short circuit; overload; various protective overheating

⑹, to provide multi-channel passive dry contact output signal

⑺, 19-inch standard rack

⑻; input and output electrical isolation; output voltage; frequency; stable; reliable

AND48 telecommunications power inverter (48V input) main technical parameters:

Model / Series

AND48-1001

AND48-1002

AND48-1003

Nominal capacity

1KVA

2KVA

3KVA

DC input

Rated voltage

48V

Allowable variation range

40~57V

Anti-irrigation noise current

10%

AC input

Voltage

220V±20%

frequency

50Hz ± 5%

AC output

Voltage

220V±1%

frequency

50Hz ± 0.5%

Power Factor

≥0.7

Dynamic characteristic

When the load current is from 25% to 50% to 75% of mutations; output voltage variation ≤10%; recovery time (20ms

Waveform distortion

(3% (linear load)

Conducted interference limits

0.15 ~ 0.5MHz, the quasi-peak (79dB, the average (66dB; 0.5 ~ 30MHz, the quasi-peak (73dB, the average (60dB

effectiveness

) 85%

Overload

120% of rated load current when; 10s automatically switches to bypass; automatic recovery after overload disappears

Bypass conversion time

(4ms

noise

(50dB

Crest Factor

3: 1

Protection

enter

Overvoltage, undervoltage protection

Over Temperature

When the internal temperature ≥85 ℃ automatically converted to the bypass

Input short circuit

Limiting, fuse and circuit breaker protection

malfunction

Automatic conversion to bypass

Alarm

AC bypass down

Buzzer every 4s tweet, automatically muted after 30s

DC input undervoltage

The buzzer beeps every 1s

overload

Overload indicator light, buzzer sounding

malfunction

Fault indicator light, buzzer sounding

LCD / LED

LCD display

Input and output voltage; frequency; battery voltage; load power; temperature; working conditions

LED indication

Mains; work; overload; DC bias; failure

surroundings

temperature

0~40℃

Relative humidity

20% to 90% (non-condensing)

Insulation resistance

500VDC.) 2MΩ

Dielectric strength

1500VAC; 1 min; leakage current (10mA

The above data for the reference data, subject to change without notice.