Gas flow meter, flow meter gasoline prices, gasoline flowmeter manufacturers, gasoline meter shelf

Gas flow meter, flow meter gasoline prices, gasoline flowmeter manufacturers, gasoline meter shelf

Product description:

Working Pressure: 42 (MPa) Nominal Diameter: DN15-DN2100 (mm) Working temperature: 450 (℃)
Custom processing: Measuring range: 0.1-55800 (m3 / h) Type: impulse type flowmeter
Model: SBL Specifications: gasoline flowmeter Accuracy: 0.5
Brand: fine River Medium: gasoline, liquid

Keywords: Gas flow meter, flow meter gasoline prices, gasoline flowmeter manufacturers, gasoline meter shelf
(Petrol meter Source)
In the sixties used in industrial flow measurement, mainly used to solve high-viscosity, low Reynolds number fluid flow measurement, has experienced a pneumatic table and electric table two stages of development, SBL Series Intelligent Target Flowmeter is in the original strain Chip-based target flowmeter measurement principle based on the use of the latest capacitive force sensor as a measurement and transmit sensitive components, while the intelligent use of modern digital processing techniques and developed a new flow measurement instruments.
(Gasoline flowmeter Product Overview)
Xiamen Jing Chuan SBL series petrol meter, using new capacitive force sensor with high sensitivity, accuracy, no moving parts, small pressure loss. Its unique anti-vibration, dirt-resistant, high sensitivity characteristics, especially for high viscosity, dirty media, easy to pour and so easy to block the flow measurement difficult conditions, are widely used in gas, coke oven gas, blast furnace gas, producer gas, compressed air, heavy oil, residual oil, tar, asphalt, sewage flow measurement and other media. Plug-in structure, easy to install, maintenance-free no-clean, especially for the large pipe, square pipe, widely used in petroleum, chemical, metallurgical, power, pharmaceutical, environmental protection, food and other fields.
• For diameter range is wide: Φ10 ~ Φ2000 to more;

• for a variety of media: gas, liquid (including high viscosity liquids, slurries), steam;
• wide temperature range: -196 ° C ~ 500 ° C;
• For high / low pressure working condition: 0 ~ 42MPa;
• For low flow rates medium flow rate of the lowest measurable 0.08m / s.

(Gasoline flowmeter principle)
When the medium flows in the measuring tube, the kinetic energy of the Target by its own generating pressure, the force generated on the target plate, so that the target plate displacement trace, the size of the force proportional to the square of its velocity and media The mathematical formula:
F = Cd`A`ρ`V2 / 2
F: Target suffered force
Cd: fluid resistance coefficient
A: Target axial projection area of ​​the measuring tube
ρ: density of the medium conditions
V: medium in the measuring tube characteristic velocity
Target suffered the force transmitted through the target rod elastomer sensors produce small changes, through circuit switching, outputs a corresponding electrical signal.
Uses sensors is crucial core of the new product truly high precision and high stability, completely changed the original target flowmeter drift strain, anti-overload (shock) is poor, there is a static sealing point and various other restrictions, not only played the original target flowmeter technology, but also has a measurement accuracy of volumetric flowmeter comparable, coupled with its unique anti-jamming, anti-impurity properties, can replace conventional flow metering flow can be measured in addition to problems, especially with a good adaptability in low flow, high viscosity, easy to pour easily blocked, high temperature, highly corrosive, strong vibration and other flow measurement in difficult conditions. Has been widely used in metallurgy, petroleum, chemical, energy , food, environmental protection and other fields flow measurement.
(Petrol meter product parameters)
Product Name: Gasoline meter
Diameter: DN15 ~ DN500mm
Nominal pressure: 0.6 ~ 42MPa
Conditions Temperature: + 500 ℃ ~ -200 ℃
Conditions Temperature: -20 ~ + 300 ℃ (need higher temperatures please contact the factory)
Accuracy: ± 0.2 ~ ± 2.5% FS
Range ratio: 1:10
Housing: Carbon steel, 304 stainless steel (or by user request consultations provided)
Power supply: Built-in 3.6VDC lithium battery (two-for-one, without signal output); external supply 24VDC (with output)
Output signal: 4 ~ 20mA two-wire system; pulse 0 ~ 1000HZ; Hart communication; RS232 / RS485 (or by user request consultations provided)
Protection class: IP65; IP67
Explosion-proof mark: intrinsically safe ExiallCT4; flameproof ExdllCT4
Meter Display: cumulative flow; instantaneous flow; temperature conditions; pressure conditions (temperature and pressure compensation type only); rod percent of full scale; fault detection
Connecting flanges: GB (GB / T) series; Chemical (HG) series; mechanical (JB / T) series; customers can also request States flange standard
Connection: pipe flange (DN15-300mm); plug-in (DN100- DN3000mm to larger).
(Petrol meter Features)

`Whole capacitive gasoline flowmeter no moving parts in the design, convenient capacitive gasoline meter structure, demolition
`Capacitive gasoline flowmeter can choose a variety of corrosion and high temperature resistant materials (such as Hastelloy, titanium, etc.)
`Machine no dead do, fully sealed (welded form), no leakage point, can be resistant to high pressure 42MPa
`Sensor is not in contact with the measured medium, there is no wear and tear parts, the use of safe and reliable
`Situ using a dry calibration method, which uses weights hanging weight method. One-button operation can complete calibration
`Capacitive gasoline meter has an optional low-cut, non-linear correction, selectable filter time
`Measurement accuracy, precision can reach 0.2%
`Capacitive gasoline flowmeter features self-test procedures, failure phenomenon glance
`Repeatability, generally 0.05 to 0.08%, rapid
`Pressure loss, only the standard orifice 1/2 • P about
`According to the actual need to be replaced Baffles (target plate) and change the flow range
`Low-power battery-site display, capable of showing the value of online direct reading, the display screen can be read simultaneously instantaneous and cumulative flow rate and percentage bar graph
`Easy to install, easy to maintain
`Jamming, anti-impurity capacity particularly strong
`Variety of output forms, various parameters can be remote
`Anti-vibration and strong, within a certain range can be measured pulsatile flow
`Instrument in the design with no moving parts, plug-in structure, easy disassembly
`Can choose a variety of corrosion and high temperature resistant materials (such as Hastelloy, titanium, etc.)
`Machine no dead do, fully sealed (welded form), no leakage point, can be resistant to high pressure 42MPa
`Instrument equipped with a self-test procedures, failure phenomenon glance
`Sensor is not in contact with the measured medium, there is no wear and tear parts, the use of safe and reliable
`Situ using a dry calibration method, which uses weights hanging weight method. One-button operation can complete calibration
`With a variety of installation methods to choose from, such as selecting the online plug-in, low installation costs
`Have integrated temperature and pressure compensation, direct the output quality or standard side
`With optional low-cut, non-linear correction, selectable filter time
`Can accurately measure a variety of normal temperature, high temperature of 500 degrees -200 degrees temperature conditions of the gas and liquid flow rate
(Petrol meter installation requirements)
1. The high temperature (80 degrees to 500 degrees), at room temperature type (-30 degrees to 70 degrees), low temperature (-40 to -200 degrees) meter installation:
a, normal type, low temperature, high temperature type flowmeter depending on the operating conditions using horizontal, vertical or inverted mounting (with factory calibration single subject);
b, medium temperature at 300 degrees, the user response flowmeter housing insulation measures taken to prevent damage to the heat radiation header (header operating temperature of -30 to 70 degrees), the same way the operating temperature of -100 degrees below medium , but also to take freezing measures;
c, in order to ensure accurate measurement of the flow meter is required straight pipe before and after the set; (Figure 1)
d, in order to ensure the flow meter in the inspection and replacement without affecting the system work, should try to set the bypass valve (3) and shut-off valves (1,2); (Figure 1)
e, due process requires can be mounted vertically, the measured medium flow by the bottom, but also from top to bottom, but the supplier shall explain when ordering;
f, meter diameter and pipe diameter connected to try the same size, in order to reduce the flow interference, causing measurement error;
g, when the flange and clamp-on flowmeter installation, should pay attention to the inner sealing gasket between the flange hole larger than the flowmeter and process pipe diameter 6-8mm and whether coaxial, in order to avoid its interference stream affect the accuracy of measurement;
We must ensure that the fluid surface facing the target sheet strength, weld short tube height 100mm (from the pipe wall to the flange sealing surface distance) by h, the insert meter installation, the short tube and flange welded to the pipe ;( figure 2)
i, the completion of the process for the new pipeline, should first conduct an initial purge and then install the meter;
j, the outer wall of the measuring tube direction of the arrow to the measured medium flows;
k, meter housing must be grounded, if not ground conditions should explain the factory;
l, the flowmeter connecting flange specifications execute GB / T series standards, according to user requirements of special processing (in a single factory calibration date).
2, the meter is set zero (zero meter must be installed after the operation) due to capacitive force sensor and Baffles have self-respect, when the meter is not installed by horizontal orientation condition, you need to reset the meter to zero. Operational procedures for the : (can also be directly set to zero when there is no medium flowing in the pipeline, the high temperature and low temperature type flowmeter must make the pipeline operating temperature after the temperature reaches zero) a, close the valve downstream of the meter; b, slowly open the upstream of the flowmeter valves, flow meter filled medium; c, slowly open the valve downstream of the meter, so that the meter is running about 10 minutes; d, shut down the meter, the downstream valve, and to determine the pipeline flow is zero; e, zero key operation ( must operate without any magnetic tool zeroing key, otherwise zero key may not operate)

3. Precautions not permitted to directly before or after the meter measuring tube end installed valves, elbows and other parts of fluid flow pattern changed dramatically in the front and back if you need to install valves, elbows and other parts at the meter before and after the pipeline should also try to ensure that the straight sections length.

(Fine Sichuan SBL series petrol meter Typical applications)

Gas Class: gas, air, hydrogen, natural gas, nitrogen, liquefied petroleum gas, hydrogen peroxide, flue gas, methane, butane, chlorine and so on.

Liquid: heavy oil, paraffin, asphalt, sulfuric acid, edible oil, residual oil, acetone, diesel, mine water, detergent, soy sauce, gasoline, silicone oil.

Syrup, solvents, perfume, water, aviation kerosene, soap ketone water, glucose, vegetable oleic acid, salt, paste, inks, coolant.

Ethylene glycol, mineral oil, liquid sugar, hydrochloric acid, automotive coatings, resins, butter, vegetable oil, liquid oxygen, shampoo, toothpaste, gel.

Fuel oil, milk, bleaches, conditioners, soda, additives, cleaning agents, alkali, ammonia, bunker oil, chemical reagents, kerosene.

Glycerol, dyes, water, nitric acid, high-boiling organic solution, lard, alcohol, oil, ethylene, polypropylene, etc. A stupid.

Steam categories: superheated steam, saturated steam
(Company name) Xiamen Jing Chuan Automation Technology Co., Ltd.
(Company website) http: //
http: //
http: //
http: //
Changle Road, Huli District 3 (company address) Xiamen
(Phone) 0592-5630657
(7X24 hours) 15859215896 (Yu Gong)
(QQ) 443569383

(Production capacity) design production capacity of one million units per year
(Service) product from the date of the factory within 12 months from the Warranty Services, appears human damage quality problems, the company responsible for repair, replacement or return, outside the guarantee period to provide paid maintenance services for life.