Dairy meter lighthouse, lighthouse best dairy meter lighthouse dairy flowmeter manufacturers

Dairy meter lighthouse, lighthouse best dairy meter lighthouse dairy flowmeter manufacturers

Product description:

Working pressure: 6.4 (MPa) Nominal diameter: DN4-DN3000 (mm) Working temperature: 350 (℃)
Custom processing: Measuring range: 0-33500 (m3 / h) Type: fluid oscillator flowmeter
Model: LUGB Specifications: Dairy meter lighthouse Accuracy: 0.5
Brand: Other Medium: Dairy products
Keywords: : Dairy meter lighthouse, lighthouse best dairy flowmeter, flowmeter manufacturers lighthouse meter lighthouse dairy, dairy meter lighthouse, lighthouse dairy flowmeter manufacturers
( Dairy flowmeter manufacturer ) Xiamen Jing Chuan Automation Technology Co., Ltd.
(Company website) http: //www.xmjingchuan.cn/
http: //www.liuliangji360.com/
http: //www.xmjingchuan.com/
http: //www.wolunliuliangji.net
http: //www.jcdcs.com/
http: //www.liuliangji5.com/
Changle Road, Huli District 3 (company address) Xiamen
(Phone) 0592-5630657
(7X24 hours) 15859215896 (Yu Gong)
(QQ) 443569383
(Production capacity) design production capacity of one million units per year
(Service) product from the date of the factory within 12 months from the Warranty Services, appears human damage quality problems, the company responsible for repair, replacement or return, outside the guarantee period to provide paid maintenance services for life.
( Dairy flowmeter source)
In the sixties used in industrial flow measurement, flow measurement is mainly used to solve high-viscosity, low Reynolds number fluid has undergone pneumatic and electric table table two stages of development. LUGB ( series Dairy flowmeter It is in the original strain gage Dairy flowmeter Basic measurement principle based on the use of the latest capacitive force sensor as a measurement and transmit sensitive components, while the intelligent use of modern digital processing techniques and developed a new flow measurement instruments.
( Dairy flowmeter product description)
Xiamen Jing Chuan LUGB series Dairy flowmeter , Using new capacitive force sensor with high sensitivity, accuracy, no moving parts, small pressure loss. Its unique anti-vibration, dirt-resistant, high sensitivity characteristics, especially for ) , High viscosity, dirty media, easy to pour and so easy to block the flow measurement difficult conditions, are widely used Dairy products. Gas, coke oven gas, blast furnace gas, metering flow furnace gas, compressed air, fuel oil, residual oil, tar, asphalt, sewage and other media occur. Plug-in structure, easy to install, maintenance-free no-clean, especially for large pipe on the square pipe, widely used in petroleum, chemical, metallurgical, power, pharmaceutical, environmental protection, food and other fields.
• For diameter range is wide: Φ10 ~ Φ2000 to more;
• for a variety of media: gas, liquid (including high viscosity liquids, slurries), steam;
• wide temperature range: -196 ° C ~ 500 ° C;
• For high / low pressure working condition: 0 ~ 42MPa;
• For low flow rates medium flow rate of the lowest measurable 0.08m / s.
( Dairy flowmeter Product Principle)
When the medium flows in the measuring tube, the kinetic energy of the Target by its own generating pressure, the force generated on the target plate, so that the target plate displacement trace, the size of the force proportional to the square of its velocity and media The mathematical formula:
F = Cd`A`ρ`V2 / 2
F: Target suffered force
Cd: fluid resistance coefficient
A: Target axial projection area of ​​the measuring tube
ρ: density of the medium conditions
V: medium in the measuring tube characteristic velocity
Target suffered the force transmitted through the target rod elastomer sensors produce small changes, through circuit switching, outputs a corresponding electrical signal.
Uses sensors is crucial core of the new product truly high precision and high stability, completely changed the original target flowmeter drift strain, anti-overload (shock) is poor, there is a static sealing point and various other restrictions, not only played the original target flowmeter technology, but also has a measurement accuracy of volumetric flowmeter comparable, coupled with its unique anti-jamming, anti-impurity properties, can replace conventional flow metering flow can be measured in addition to problem, particularly in low flow, high viscosity, easy condensate easy to block, high temperature, highly corrosive, strong vibration and other flow measurement in difficult conditions has good adaptability. has been widely used in dairy products, metallurgy, petroleum, flow chemical, energy, food, environmental protection and other fields of measurement.
( Dairy flowmeter Spec)
product name: Dairy flowmeter
Diameter: DN15 ~ DN500mm
Output signal: 4 ~ 20mA two-wire system; pulse 0 ~ 1000HZ; Hart communication; RS232 / RS485 (or by user request consultations provided)
Nominal pressure: 0.6 ~ 42MPa
Conditions Temperature: + 500 ℃ ~ -200 ℃
Conditions Temperature: -20 ~ + 300 ℃ (need higher temperatures please contact the factory)
Protection class: IP65; IP67
Explosion-proof mark: intrinsically safe ExiallCT4; flameproof ExdllCT4
Accuracy: ± 0.2 ~ ± 2.5% FS
Range ratio: 1:10
Housing: Carbon steel, 304 stainless steel (or by user request consultations provided)
Power supply: Built-in 3.6VDC lithium battery (two-for-one, without signal output); external supply 24VDC (with output)
Meter Display: cumulative flow; instantaneous flow; temperature conditions; pressure conditions (temperature and pressure compensation type only); rod percent of full scale; fault detection
Connecting flanges: GB (GB / T) series; Chemical (HG) series; mechanical (JB / T) series; customers can also request States flange standard
Connection: pipe flange (DN15-300mm); plug-in (DN100- DN3000mm to larger).
( Dairy flowmeter Features)
`Whole Dairy flowmeter No moving parts in the design. Dairy flowmeter Structure, easy removal
` Dairy flowmeter You can choose a variety of corrosion and high temperature resistant materials (such as Hastelloy, titanium, etc.)
`Machine no dead do, fully sealed (welded form), no leakage point, can be resistant to high pressure 42MPa
`Sensor is not in contact with the measured medium, there is no wear and tear parts, the use of safe and reliable
`Situ using a dry calibration method, which uses weights hanging weight method. One-button operation can complete calibration
` Dairy flowmeter With optional low-cut, non-linear correction, selectable filter time
`Measurement accuracy, precision can reach 0.2%
` Dairy flowmeter Equipped with self-test procedures, failure phenomenon glance
`Repeatability, generally 0.05 to 0.08%, rapid
`Variety of output forms, various parameters can be remote
`Anti-vibration and strong, within a certain range can be measured pulsatile flow
`Instrument in the design with no moving parts, plug-in structure, easy disassembly
`According to the actual need to be replaced Baffles (target plate) and change the flow range
`Low-power battery-site display, capable of showing the value of online direct reading, the display screen can be read simultaneously instantaneous and cumulative flow rate and percentage bar graph
`Easy to install, easy to maintain
`Jamming, anti-impurity capacity particularly strong
`With optional low-cut, non-linear correction, selectable filter time
`Situ using a dry calibration method, which uses weights hanging weight method. One-button operation can complete calibration
`With a variety of installation methods to choose from, such as selecting the online plug-in, low installation costs
`Have integrated temperature and pressure compensation, direct the output quality or standard side
`Pressure loss, only the standard orifice 1/2 • P about
`Can choose a variety of corrosion and high temperature resistant materials (such as Hastelloy, titanium, etc.)
`Machine no dead do, fully sealed (welded form), no leakage point, can be resistant to high pressure 42MPa
`Instrument equipped with a self-test procedures, failure phenomenon glance
`Sensor is not in contact with the measured medium, there is no wear and tear parts, the use of safe and reliable
`Can accurately measure a variety of normal temperature, high temperature of 500 degrees -200 degrees temperature conditions of the gas and liquid flow rate
( Dairy flowmeter Installation and commissioning on request)
1. The high temperature (80 degrees to 500 degrees), at room temperature type (-30 degrees to 70 degrees), low temperature (-40 to -200 degrees) meter installation:
f, meter diameter and pipe diameter connected to try the same size, in order to reduce the flow interference, causing measurement error;
g, when the flange and clamp-on flowmeter installation, should pay attention to the inner sealing gasket between the flange hole larger than the flowmeter and process pipe diameter 6-8mm and whether coaxial, in order to avoid its interference stream affect the accuracy of measurement;
We must ensure that the fluid surface facing the target sheet strength, weld short tube height 100mm (from the pipe wall to the flange sealing surface distance) by h, the insert meter installation, the short tube and flange welded to the pipe ;( figure 2)
i, the completion of the process for the new pipeline, should first conduct an initial purge and then install the meter;
c, in order to ensure accurate measurement of the flow meter is required straight pipe before and after the set; (Figure 1)
a, normal type, low temperature, high temperature type flowmeter depending on the operating conditions using horizontal, vertical or inverted mounting (with factory calibration single subject);
b, medium temperature at 300 degrees, the user response flowmeter housing insulation measures taken to prevent damage to the heat radiation header (header operating temperature of -30 to 70 degrees), the same way the operating temperature of -100 degrees below medium , but also to take freezing measures;
d, in order to ensure the flow meter in the inspection and replacement without affecting the system work, should try to set the bypass valve (3) and shut-off valves (1,2); (Figure 1)
e, due process requires can be mounted vertically, the measured medium flow by the bottom, but also from top to bottom, but the supplier shall explain when ordering;
j, the outer wall of the measuring tube direction of the arrow to the measured medium flows;
k, meter housing must be grounded, if not ground conditions should explain the factory;
l, the flowmeter connecting flange specifications execute GB / T series standards, according to user requirements of special processing (in a single factory calibration date).
2, the meter is set zero (zero meter must be installed after the operation) due to capacitive force sensor and Baffles have self-respect, when the meter is not installed by horizontal orientation condition, you need to reset the meter to zero. Operational procedures for the : (can also be directly set to zero when there is no medium flowing in the pipeline, the high temperature and low temperature type flowmeter must make the pipeline operating temperature after the temperature reaches zero) a, close the valve downstream of the meter; b, slowly open the upstream of the flowmeter valves, flow meter filled medium; c, slowly open the valve downstream of the meter, so that the meter is running about 10 minutes; d, shut down the meter, the downstream valve, and to determine the pipeline flow is zero; e, zero key operation ( must operate without any magnetic tool zeroing key, otherwise zero key may not operate)
3. Precautions not permitted to directly before or after the meter measuring tube end installed valves, elbows and other parts of fluid flow pattern changed dramatically in the front and back if you need to install valves, elbows and other parts at the meter before and after the pipeline should also try to ensure that the straight sections length.