Product description:

Port size: with 1 / 2-14NPT conduit with threaded ends and terminals and supporting the test piece (mm) Custom processing: Protection: IP65
Measuring range: 0-1035 ~ 41370kPa (kPa) Type: Capacitive Pressure Transmitter Explosion-proof grade: flameproof dllCT5
Model: JC3351DP Measuring media: liquid, gas or vapor Accuracy class: ± 0.25%
Brand: fine River Output signal: 4 ~ 20mA output HART® protocol superimposed digital signal (two-wire) (mA) Power supply: External power supply 24VDC (supply range 12V ~ 45V) (V)









JC3351DP series capacitive differential pressure transmitter


Performance parameters:


Using the object: liquid, gas and steam
Measuring range: 0-0.1kPa to 40MPa
Accuracy: ± 0.2%, ± 0.5%
Output signal: 4-20mA DC
Power supply: 12-45V DC, typically 24V DC (see load characteristic diagram)
Indicators: Analog linear indication 0-100% scale and the square root instructions 0-10 scale, and 3 1/2 digit LCD liquid crystal display (0-100% linear)
Explosion:. A flameproof dⅡBT4
b. Intrinsically safe iaⅡCT6
Span and zero: External continuously adjustable
Negative migration: positive, negative direction migration can be measured in the range, the lower limit and within no more than set the measurement range of the sensor.


temperature range:


1, ambient temperature: -40 ~ + 85 ℃, -20 ~ + 65 ℃ (with instruction sheet)
2, the measurement medium temperature: -40 ~ + 120 ℃
3, Storage Temperature: -40 ~ + 105 ℃
Relative humidity: 0-100%
Static pressure and overload pressure: 4,10,25,32MPa
Draw volume amount: (0.16cm (SUP) 3 (/ SUP)
Damping (mediated jump response): When filling silicone oil, generally continuously adjustable between 0.2s to 1.67s
Stability: within six months does not exceed the maximum range of the absolute value of the basic error
Temperature effects: (maximum time span)
For DP, GP; range 4-0 Transmitter Code (± 0.2% max range / 10 ℃, other types and range of the transmitter doubled.
Static pressure effects (when maximum range)
For HP type transmitters (± 0.2% maximum range of other types of transmitters (± 0.4% maximum range, available online correction.
Vibration effects: on any axis, the vibration frequency is 200HZ, error of measuring range upper limit was 0.05% URL / g


Structural materials:


Diaphragm: 316L stainless steel, Hastelloy C-276, Monel, or tantalum
Drain / vent valve: 316L, Hastelloy or Monel optional -276
Flanges and Fittings: nickel-plated steel, 316L stainless steel, Hastelloy C or Monel
Contact with the media '0' rings, Yuqing, Viton
Fill Fluid: silicone oil or inert oil
Bolts: Carbon steel nickel plated
Electronic housing material: Low-copper aluminum
Lead Pressure Connection: 1, cited pressure holes NPT1 / 4 'inner tapered pipe thread
2, cited pressure connectors
Electrical connection hole: M20 * 1.5 or NPT1 / 2
Weight: about 3.9kg (without accessories)