Intelligent Vortex flowmeter, LUGB pipeline vortex flowmeter, vortex flowmeter Xiamen

Intelligent Vortex flowmeter, LUGB pipeline vortex flowmeter, vortex flowmeter Xiamen
 

Product description:

Custom processing: Brand: fine River Model: JC-LUGB
Type: fluid oscillator flowmeter Measuring range: 1: 20 (m3 / h) (m3 / h) Accuracy class: ± 1.0%
Nominal diameter: DN15-300 (mm) (mm) Suitable medium: liquid, gas or steam Working pressure: 1.6Mpa, 2.5Mpa, 4.0Mpa (MPa) (MPa)
Working temperature: -20 ℃ ~ + 60 ℃ (℃) (℃)

Jing Chuan JC-LUGB Vortex Flowmeter

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

I. Product Overview:

Jing Chuan JC-LUGB Vortex flowmeter is based on fluid Carmen ( karman ) Principles, and developed into a new type of meter used to measure gas, vapor or liquid flow, and as flow transmitters used in automation and control systems. The series meter uses advanced differential technology, with isolation, shielding and filtering measures, greatly improving the earthquake resistance, overcoming the small signal data disorders and other problems, and uses a unique sensor packaging technology and protective measures to ensure the reliability of the product. Fine River JC-LUGB Vortex flowmeters are widely used in large, medium and small variety of pipes and drainage of industrial wastewater treatment cycle oil and chemical reagent metering, as well as compressed air, saturated and superheated steam, gas and a variety of media traffic.

Jing Chuan JC-LUGB Vortex Flowmeter divided into common type and temperature and pressure compensation type two. Normal refers to the measurement of a single traffic signal, temperature and pressure compensation type can be achieved simultaneously measure temperature, pressure, flow rate. Each form has split and one type two options to accommodate and facilitate the different installation environment.

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

Second, the principle:

Jing Chuan JC-LUGB Type vortex flowmeter is spread by direct contact with fluid vortex generator, detection probe and the corresponding electronic circuits and other components. When the vertical vortex generator placed in the fluid flow through the housing, alternately produce two columns on both sides behind Whirlpool (see below), this vortex is called Karman vortex. Strouhal on the basis of Karman vortex theory proposed the Karman vortex frequency is proportional to the flow rate of the fluid, and gives the frequency and velocity The relationship equation:

Where: f- vortex separation frequency (HZ); U

within u- line fluid average velocity (m / s); f = `Sr

d- vortex generating body facing the flow width; (1-1.25d / D)

D- inner diameter of the sensor housing;

Sr- Strouhal number, a dimensionless number. For certain cylindrical vortex body occurs within a certain flow range is a function of the Reynolds number in the range of the normal flow can be considered constant.

From the above equation, the flow in the vortex generator welcome width d and Strouhal number Sr is known conditions, it can be determined the average velocity of the fluid in the pipe and volume flow Qv U by measuring the vortex shedding frequency

Qv = 3600`Uπ (D / 2) 2

Fluid sensor is the unit volume flow Qv The number of pulses generated n Called the sensor meter factor K :

n

K= ( N / m 3 )

Q

Alternating force generated by the swirl on the detection probe, so that the internal embedded piezoelectric element generates a charge frequency signal detected by the pre-conversion processing electrical amplification, the output is proportional to the volume flow of the pulse signal, or replace the standard signal output connected with flow indicator and temperature, the pressure sensor, calculates various parameters, display and cumulative like.

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

Third, the product features:

Jing Chuan JC-LUGB Type vortex flowmeter has the following characteristics:

  • Delicate and firm structure, no moving parts, long-term stable operation;
  • Installation is simple and flexible, easy to maintain;
  • The output signal is pulse frequency signal, high precision, zero drift;
  • Structural forms, there is ducted and plug-in, split and one-to choose from;
  • Accuracy, measurement accuracy is typically liquid is ± 1.0%, the measurement accuracy of the gas ± 1.5%;
  • Wide measuring range, at a Reynolds number of 2X104-7X106 Within the range up to 1:20;
  • Pressure loss is small, low operating costs, meaning more energy-efficient;
  • Low power consumption, battery durability, strong seismic performance;
  • Cumulative flow can be power-down protection, protection time up to 10 years;

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

Fourth, the technical parameters:

Jing Chuan JC-LUGB Some basic parameters vortex flowmeter as follows:

Implementation of standards

Vortex flow sensor (JB / T9249-1999)

Meter diameter (mm)

1520253240506580100125150200250300

Nominal

1.6Mpa, 2.5Mpa, 4.0Mpa (the other can be customized)

Accuracy class

Liquid: ± 1.0%

Gas or steam: ± 1.5%, ± 1.0%

Turndown ratio

1: 101: 151: 20

Sensor material

304, 316 (L) stainless steel

Environmental conditions

Medium temperature: -40 ℃ ~ + 250 ℃, -40 ℃ ~ + 350 ℃

Ambient temperature: -20 ℃ ~ + 60 ℃

Relative humidity 5% to 90%

Atmospheric pressure 86 ~ 106Kpa

Power supply

A: external power supply, + 24VDC ± 15%, ripple ≤ ± 5%, applicable to 4-20mA output, pulse output, RS485, etc;

B: internal power supply, a group 3.0V10AH lithium battery, the battery voltage can work properly when 2.0-3.0V.

Signal output

Pulse signal, 4-20mA current signal

Communication output function

RS485, hart protocol communications

Signal line interface

Common type: Horsman joints or comes three core cable;

Explosion-proof: internal thread M20 * 1.5

Explosion levels

ExiaIICT5 or ExdIIBT6

Protection class

IP65 or higher (can be customized)

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

V. Model Description and Selection:

JC-LUGB- • - • - • - • - • - • - •
① ② ③ ④ ⑤ ⑥ ⑦
①: Link way: two flange connection (1) and clamping flange (2);

②: Measuring media: into gas (1), liquid (2) and steam (3);

③: Nominal size (unit mm): DN15-DN300
④: structure: divided into one formula (Z) and Split (F);

⑤: Header Type: divided into the following categories:

N-type: + 12V or 24V power supply, three-wire output pulse signal;

Type A: + 24V supply, the output wire 4-20mA

Type B: internal lithium battery-powered, live shows, no signal output;

Type C: + 24V power supply, live display, output two-wire 4-20mA;

Type D: + 24V power supply, live shows, RS485 communication;

E type: + 24V power supply, live shows, Hart communication;

F type: integrated temperature and pressure compensation for saturated steam;

G type: integrated temperature and pressure compensation for superheated steam and gases in general;

⑥: Explosion levels: no explosion points (N) and intrinsically safe (E1), flameproof (E2);

⑦: Pressure rating: sub-routine (N) and high pressure (H);

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

Sixth, the installation instructions:

On the diameter of the corresponding pipe flow meter should be installed in a horizontal, vertical, inclined (fluid flow from bottom to top) is. It should also be free to install the mechanical vibrations of the pipeline upstream and downstream of the meter should be configured a certain length straight pipe, its length should comply with the requirements in the following table.

Upstream pipeline form

Upstream straight pipe length

Downstream straight pipe length

Concentric tube fully open valve

12DN

5DN

Concentric contraction full gate

15DN

One 90 elbow

20DN

The same plane two 90 elbow

25DN

Two different planes 90 elbow

40DN

Regulating valve, the half-open gate

50DN

The inner diameter of the straight pipe section as consistent path through the sensor, if not the same, should be taken slightly larger than the diameter of the pipe sensor error to ≤ + 3%, and not more than 5mm.

1, the flow meter is installed in horizontal pipelines: the measurement of gas flow, if measured gas contains a small amount of liquid, flow meter should be installed at the online high; when measuring liquid flow rate, if measured body contains a small amount of gas , the meter should be installed at the lower line.

2, the meter is installed vertically in the pipeline: the measurement of gas flow meter can be installed in a vertical pipeline if they are contained in the gas under a small amount of liquid, gas flow measurement of liquid flow should be upward, the liquid flows by bottom up. .

Similar names are: turbine flowmeter, gas turbine flowmeter, flowmeters, electromagnetic flowmeters, vortex flowmeters, pipeline flow, gas flow, flow measurement

Sincerely!

Xiamen Jing Chuan Automation Technology Co., Ltd.

Advanced technology initiative to recommend, shrewd mind purchasing choice.

Yu Zhiping *************** ***************

Tel: 0592-2657355

Fax: 0592-2657355

Mobile: 15859215896

QQ: 443569383

Website: www.xmjingchuan.com

Address: Xiamen Huli District Yuehua Road, Building 2, Building 151 Howley 5 layers

Postal Code: 361006