Horizontal movement treadmill load analysis system

Horizontal movement treadmill load analysis system

Product description:

Horizontal movement treadmill load analysis system

(For more details, please visit: http: //www.huaruison.com)

Beijing Hua Ruisen Technology Development Co., Ltd. China Regional Sales: Germany Sana cardio 150L Horizontal movement collapsed car ECG load analysis system specially adapted to the Department of Nuclear Medicine, Cardiology and other departments; safety testing is based on horizontal / semi Horizontal Technology dynamometer.

Germany Sana cardio 150L Horizontal movement collapsed car can be used for normal horizontal horizontal / semi Horizontal security force.

Germany Sana cardio 150L Horizontal movement collapsed car movement collapsed car in a special security, for example, after cardiac infarction or catheterization, cardiovascular disorders suspected pressure testing; there are other special exercise load applications, such as in do cardiovascular examination, you need to use this dynamometer pressure reply dynamometer loungers are also recommended for the elderly and disabled patient examination.

Germany Sana cardio 150L Horizontal movement collapsed car technical parameters of European safety standards: DIN 13405 and DIN VDE 0750-238 brake principle: eddy current brake torque measuring device consists of a computer-controlled, independent of revolutions per minute (that has nothing to do with the speed).

Load Range: 20-800 watts Speed ​​range: 30-130 rev / min load accuracy: 3%, less than 3 watts of load setting: Set according to the load on the internal procedures; through the interface is set by an external host computer, a minimum accuracy of 1 W; manual settings can be performed at 5 watts -25 watts per grade.

Load Program: 5 sets of freely programmable dynamometer procedures; 1 set of automatic control pulse steady state program Interval: 1-99 minutes

Germany Germany Sana cardio 150L Horizontal movement collapsed car original blood pressure analysis parameters:

Pulse measurement: priority principle -1 ECG; 2. opto; 3. RR; measuring range 35-240 beats.

Blood pressure measurement: RR revision system uses a special indirect measurement; distortion during the measurement, the computer parsing and correction due to interference caused; to 3mmHg / pulse speed automatic release of pressure, rapid release of pressure at high amplitude equilibrium.

Loungers parameters: size 90 * 1375px, height adjustable from 140-5125px; maximum load 160kg through precise control, you can adjust the seat and pillows to the most suitable position of the patient is provided with a pillow below 1250px wide drum-shaped frame. . recliner position can be tilted from 45 ° (exercise position) to a flat position continuously adjustable tilt angle is adjusted by precise control of.

Riding help handle: On the left side of the head is equipped with an adjustable handle can be fixed, it can help patients up and down the deck chairs.

Germany Germany Sana cardio 150L Horizontal movement collapsed car Options: Domestic ECG analysis system load

Domestic load ECG Analysis System Technical parameters:

The real synchronous 12-lead ECG test and measurement analysis

Real-time exercise ECG continuous recording, do not miss any second of ECG changes;

Full-lead ECG in real-time on-line analysis and storage.

Digital collection; RFA increment filtering technology / hardware module digital down dry / intelligent anti Zero Drift system; high quality; high-resolution ECG obtained;

Correspondence analysis sporty ST segment;

ST analysis and graphical real-time display and post-processing capabilities

Versatile multi-sport presets and custom exercise program

Report Optional / multi edit mode / database statistics

Powerful database statistical functions; network compatible.

It supports a variety of operating systems; automatic exercise ECG test; abnormal situation prompts alert

Extended Feature Support: exercise blood pressure, real-time thermal printer

Digital ECG signal acquisition system

Through a standard RS-232 / USB communication interface, isolation voltage up to 4000V between data communication and control complete with computers.

Using the latest 'isolation communication signal energy conversion' technology does not require any additional power supply or battery support, can complete a variety of ECG lead system amplification and analog to digital conversion.

Sampling rate per channel 1000S / s, sampling accuracy 14

Multiple digital filter makes clear and accurate recording results

RFA increment filtering techniques (ECG graph Enhancer-Finite Residual Filter Algorithm algorithm), hardware digital noise reduction module, even in the state of motion (baseline drift / twitch / electromagnetic interference and other factors), but also to extract the signal, resulting in a clear and effective detailed ECG ST segment analysis and evaluation. do not change the analysis of ECG, ECG measurement evaluation table and the original QRS wave, in order to gain valuable ECG.

Beijing Science and Technology Development Co., Ltd. Hua Ruisen

2 seat on the 16th floor, Building A perfect circle square and Guanghua Road Beijing Tongzhou District, Tongzhou Industrial Development Zone

Tel / Fax: 010-57118919 (straight line) 010-51266093 (switchboard) 18001279800

QQ: 1275041125

Postal Code: 101113

E-mail:. Huarui51266093 @ 163 com

http: //www.huaruison.com