Closed loop water beside the water processor

Closed loop water beside the water processor
 

Product description:

SCLL series water processor for microorganisms (such as bacteria and algae) breeding of purification of water quality, the principle that water flow SCLL type water processor, the ecological environment of bacteria and algae in the water changes, the living conditions of loss and death. Specific performance three aspects:
Any kind of living organism has its specific biological field. Charge distribution in vivo movement, influenced by changes in the electric field in vitro environment, thus affecting the body's life activities. Microorganism on Earth generally only adapt and survive in the Earth electric field strength (130v / m) surface; and change the electric field strength; may alter or affect the bacteria (E.Coli) physiological metabolism, such as gene expression programs, activity, so that the survival of abnormal bacteria, which is the cause of bacterial death one.
There are many cell membrane channels. Through these channels, cell contact with its surroundings. The channel is formed by a single molecule or molecular complex composition, allowing ions to pass through. Adjusting affect the function of ion channels in cell life and cell outer field destroys the ion channels on the cell membrane, changing the internal current mediate cell function, thus affecting the bacteria's life. bacterial liquid flows through a strong electric field, causing the instantaneous change in the current through the liquid on the conductive path cells are lethal electronic shock of high-speed movement to achieve the purpose of sterilization.
Field water treatment process; DO get activated; produce O 2- , `OH, H 2O2 as well as 1 O2 And other reactive oxygen species (O 2- Superoxide anion radical. `OH radicals is. H 2O2 When hydrogen peroxide. 1 O2 When the singlet oxygen). ROS collective microorganisms can produce a series of deleterious effects of aging is caused by the organism main reason. O 2- Can damage important biological molecules, causing microbes body injury; O 2- Gift machine microbial organism membrane peroxidation and accelerated aging.

Anticorrosive works
ROS generation oxide film on the new wall.
Microbiologically influenced corrosion, corrosion is suppressed silence.
Scaling, cleaning works
After SCLL water processors; reduce the degree of polymerization of water molecules; structural deformation; generating a series of minor changes in the physical and chemical properties of elasticity; such as: water dipole moment increases, the polarity increases, thereby increasing the water capacity of the water and and the ability to dissolve dirt.
Water contains salt ions such as Ca 2+ , Mg 2+ By the gravitational field, the arrangement is changed, it is difficult to accumulate the wall tends to prevent fouling class generation. Specific energy field changes CaCO 3 Crystallization process, suppressing generation of calcite, provide energy generating text crystallization.
Suspended particles and colloids in water after treatment the surface Zeta potential changes destabilization tends flocculation precipitation. The precipitate was washed to remove water or sewerage, water purification.
The treated water reactive oxygen species. Reactive oxygen mixed crystallization process, accelerate colloidal stability for the system has been scaling active oxygen will destroy scale electron binding force between molecules, changing the crystal structure, the hard old dirt becomes loose soft dirt, so fouling gradually falling off, and even pieces, debris shedding, achieve the purpose of cleaning

Product Introduction
SCLL-F, G series circulating water next to the water processor is based on the original fully pipelined processors developed out of the water processor uses the principle of high frequency oscillating electric field, and automatically adjust the signal processing based on water quality, and only use next to the stream processing successful development of this technology in the international leading level product is suitable for circulating water system disinfection, algae, descaling treatment and removal of suspended solids.

Features
  • Just next to the stream processing system 1-3% water flow, installation easier.

  • Powerful pulsed electric fields to kill Legionella.

  • Without chemicals, no secondary pollution, green.

  • Rust dirt to remove the yellow water.

  • Reduce turbidity.

  • Visual effects visible.

Features
• kill bacteria in the water
• kill Legionella
• Inhibit algae
• waterproof scale, descaling
• Anti-corrosion pipeline equipment
• remove suspended solids
Adaptation
  • Central air conditioning cooling, cooling water system

  • Cooling water circulation systems

  • Industrial cooling water circulation system

  • Various heat exchange system and cooling tower systems

Implementation of standards
Electronic water processor technical conditions HG / T3133-1998


F-type (open cooling water system special type) Dimensions and technical parameters

Technical Parameters
Input Power: ~ 220V, 50Hz
Water temperature: 0-50 ℃ H
Head loss: 4-7m
Scale cleaning efficiency: 100%
Bactericidal rate:) 99% W
Algae rate:) 97%
Legionella: to meet international standards W L
Corrosion rate: up to national standards SCLL-F type circulating water next to the water processor
Applicable water quality: total hardness (700mg / L, to CaCo 3 meter (Open cooling water systems)

Selection area (mm) Dimensions (mm) Outside over size (mm)
Head loss (m)

Maximum power (w)

weight
(Kg)
model Applicable Path Long L Width W High H Inlet and outlet diameter Outfall Path
SCLL-0100F 80 1450 720





1260
225 225 6 90 165
SCLL-0200F 100 1450 720 225 225 6 120 168
SCLL-0300F 150 1450 720 225 225 6 160 171
SCLL-0400F 200 1450 720 332 332 6 200 174
SCLL-0500F 250 1450 720 332 332 6 300 177
SCLL-0600F 300 1450 720 440 432 4 500 180
SCLL-0700F 350 1450 720 440 32 7 600 183
SCLL-0800F 400 1475 740 550 540 5 800 186
SCLL-0900F 450 1475 740 665 640 7 900 189
SCLL-1000F 500 1550 750 665 650 4-5 1100 192
SCLL-1100F 600 1550 750 880 850 5 1300 195
SCLL-1200F 700 1750 770 880 865 4 1500 198
SCLL-1300F 800 1750 770 1100 165 5 1800 201
Note: Due to the continuous improvement of the company's technology, equipment parameters may be changed Shubu notice.




G-type (closed loop water system special type) Dimensions and technical parameters
Technical Parameters
Input Power: ~ 220V, 50Hz
Water temperature: 0-95 ℃
Head loss: 0.2-1.0m H
Scale cleaning efficiency: 100%
Sterilization rate:) 99%
Corrosion rate: up to national standards
Applicable water quality: total hardness (700mg / L W
In CaCo 3 meter
L
SCLL-G type circulating water next to the water processor
(Closed loop water system)

Selection area (mm) Dimensions (mm) Outside over size (mm)
Head loss (m)

Maximum power (w)

weight
(Kg)
model Applicable Path Long L Width W High H Inlet and outlet diameter Outfall Path
SCLL-0100G 80 950 580





1320
225 225 0.2 50 102
SCLL-0200G 100 950 580 225 225 0.4 90 105
SCLL-0300G 150 950 580 225 225 0.7 120 108
SCLL-0400G 200 950 580 332 332 1.0 160 111
SCLL-0500G 250 950 580 332 332 1.0 220 114
SCLL-0600G 300 950 580 440 432 1.0 300 117
SCLL-0700G 350 950 580 440 32 1.0 500 126
SCLL-0800G 400 975 580 550 540 1.0 600 138
SCLL-0900G 450 1000 900 665 640 1.0 800 172
SCLL-1000G 500 1000 900 665 650 1.0 900 184
SCLL-1100G 600 1000 900 880 850 1.0 1100 196
SCLL-1200G 700 1100 1220 880 865 1.0 1400 246
SCLL-1300G 800 1100 1220 1100 165 1.0 1700 258
Note: Due to the continuous improvement of the company's technology, equipment parameters may be changed Shubu notice.




Selection principle
☼ Due to the difference (see table below) open and closed cycle cooling water system water system, it is necessary to use different water processor water treatment for the respective characteristics. When the F-type water processor is designed for open cooling water circulation system design. G-type water processor is designed for closed cooling water circulation system design.
Open cooling water system Closed loop water system
System Properties Water is an open system, heat release to the air in the system by evaporation of water. Water is a closed system, played the role of heat transfer.
Water concentrated or not concentrate Not concentrated
Water quality scaling tendency Strong weak
Bacteria fast slow
Algae Growth Have no

☼ open cooling water system by the system water mains path select F-type water processor, namely water processor suitable diameter and uniform diameter mains water system.
☼ closed system circulating water system by water mains path select G-type water processor, namely water processor suitable diameter and uniform diameter mains water system.
Installation legend
Recycled water

Unit 1
Recommended Installation: System pump out of the water circulating pump manifold
Bypass Installation This installation need to reprovision the pump, the more
Economy, only 1-3% sidestream system flow. Unit 2



SCLL-F , G Sewage



Optional Installation: cooling tower basin or system cooling tower
Pool from circulation installation. This installation need to reprovision through water supply
Ring pumps


unit
System water pump circulating pump SCLL-F Sewage


Design and installation instructions
  • Water working pressure 1.0MPa and 1.6MPa routine has two kinds specify when ordering special system can be designed according to user needs.

  • Design, water pump near the system should give SCLL-F, G mounting prepared. SCLL-F, the pump inlet and outlet pipe system G is connected. SCLL-F, G of the outlet and the pump inlet phase system connection.

  • SCLL-F, G, near the inlet and outlet valves and pressure gauges must be set manually, import and export pressure water water processor processor may reflect working conditions.








Equipment piping installation diagram
  • Water processor for controlling the power supply 220V, 50Hz, water processor should be installed in a better ventilated room.

  • For the new system, before the system was officially opened, you must rinse the system piping, the welding slag removal systems, wire, pipe scale and other impurities, drained of yellow rust water system.

  • For severe fouling (dirt thick) 3mm) the old system, before installing the next SCLL type of water treatment, the entire system should be pre-cleaned to prevent clogging of the old dirt off the pipe.

  • Equipment connected to the outfall line must extend the sewage ditch, extending pipe diameter piping and equipment consistent with the original diameter.