Factory direct | UPS charger | 60W switching power supply charge | UPS charge switching power supply 13.8V4A

Factory direct | UPS charger | 60W switching power supply charge | UPS charge switching power supply 13.8V4A

Product description:

Input voltage: 90 ~ 264VAC127-370VDC (V) The output voltage: 12 (V)
Voltage Regulation: 1 (%) Load regulation: 10 (%)
Output Power: 60 (W) Output ripple and noise: 100mVP-P
Types of: AC / DC Power Supply Transistor Connection: Single-ended
work efficiency: 81 (%) model: SC-60-12
Output voltage accuracy: 1 (%) Brand: Nine Year
Modulation: Pulse width modulation (PWM) of formula certified product: CE

Since the warehouse inventory changes frequently, please photographed before the store to confirm whether there is inventory, not contact the store on photographed payment without shipping. Hope to make a complex job. Thank you parents!

This product features:

• Small size; light weight; high efficiency

• universal voltage input

• with power; charging; mains display

• Protection Features: Short circuit / overload / overvoltage

• 100% full load burn-in test

• 2 year warranty


• Size 129 * 98 * 38

• enter

Voltage range: 90 ~ 264VAC 47 ~ 63Hz, 127-370VDC

Input Current: 1.6A / 110VAC 0.8 / 230VAC

The impact of current: Cold start current 40A / 230VAC

Leakage current: (1mA / 240VAC

• Output

DC output voltage 13.8V 13.4V
Rated output current 4A 0.35A
Output Power 60W
Output voltage tolerance


Start; rise; hold time: 200ms; 50ms; 30ms / 230VAC

Ripple and noise 100mVP-P

• Efficiency 81

• protection

Overload protection: 110% ~ 150% of rated output power start overload protection

Protection: AC charging mode; hiccup mode; automatic recovery after an abnormal condition is removed

Low Battery Protection: 9 to 11.5

Protection mode: Shutdown output

UPS Features:

Battery long-line float red, high charging efficiency, battery plumpness of up to 90%.

Full automatic stop charging to prevent battery overshoot, effectively extending the battery life.

Mains, battery automatic switching, no waiting time, no manual duties.

Cold start function, in the absence of electricity in the situation, you can use the battery directly start UPS, to meet the emergency needs of users.

Operating temperature and humidity: -10 ℃ ~ + 60 ℃; 20% ~ 90% RH (Refer to Derating Curve)

Storage temperature and humidity: -20 ℃ ~ + 85 ℃; 10% ~ 95% RH non-condensing

Shock resistance:. 10 ~ 500Hz, 2G 10min / 1 cycle, duration 60 minutes, each axis

Pressure resistance: between input and output: 1.5KVAC; between the input and ground: 1.5KVAC; between the output and ground: 500VAC

Insulation resistance: between input and output: 100M Ohms / 500VDC

Safety standards, protection class: Conforms to UL1012

EMC standards: EN55022, CLASS 2

Note: 1. All parameters NOT specially mentioned are measured values ​​obtained at 230VAC input, rated load and 25 ℃.

2. Ripple and noise voltage in 20MHz of bandwidth by 12 inches twisted pair end with overtime 0.1μ and 47μ capacitor measured.

3. Tolerance is the sum of the voltage setting error, voltage regulation and load regulation.

Packing: Neutral white box

Single product weight: 0.52Kg 45 Pcs / box 24Kg

Other Specifications:

Dimensions and wiring: