XSJ Series Flow Totalizer

XSJ Series Flow Totalizer
 

Product description:

Explanation:
① need for temperature, pressure compensated flow measurement and totalizer
② connected with all types of current, voltage or pulse output flow transmitters
③ 8 digital accumulated amount, four or five instantaneous volume display, the basic error of better than ± 0.2% F · S
④ 8 Line segment correction transmitter nonlinear function
⑤ Dimensions: 160 * 80 (horizontal / vertical), 96 * 48 (one shown), 96 * 96
⑥ instrument power 220V AC. (9 ~ 24) V DC
basic configuration:
Dual display, external transmitter power supply
extensions:
① alarm output, up to 2:00
② transmission output or accumulated pulse output
③ Communication Interface: RS 232 or RS 485
④ printer interface (without the printer unit)
⑤ blackout recording (security function)

Selection Tables
content
Code and description
XSJ /
Dual display, external transmitter power supply
Dimensions
A―
Horizontal 160 * 80 * 80 * 125 or 160 * 125 vertical
B―
96*96*112
C―
96 * 48 * 112, only horizontal single significant
Panel form
H
Horizontal
S
Vertical
F
Square
display method
1
8 LED single display, the cumulative value, instantaneous value switching display (limited to C-type instrument)
2
8 + 4 LED dual display, the cumulative value, instantaneous value displayed simultaneously (limited to A, B type)
Input signal (Note 1)
I
DC Current
V
DC voltage
K
Pulse input
Number of alarm points
T•
T0: No alarm T1 ~ T2: 1 ~ 2 point alarm
External power supply
B0
No external power supply
B1
External supply 24V DC, error is less than ± 5%, 50mA
B2
External supply 12V DC, error is less than ± 5%, 50mA
B3
other
Transmission output
(Independent power supply, full isolation)
A0
No output
A1
Current output (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA
A2
Voltage output (0 ~ 5) V, (1 ~ 5) V
A3
Voltage output (0 ~ 10) V
A4
Other output
Communication Interface
(Independent power supply, full isolation, 2400 ~ 19.2K instrument addresses 0 to 99, the response delay is less than 500μs)
S0
No communication interface
S1
RS-232 Interface
S2
RS-485 Interface
S3
RS 422 Interface
Instrument Power
V0
220V AC
V1
24V DC
V2
12V DC
Print function (limited to A, B-type instrument) (with hardware clock)
P
P represents print interface, can be omitted without
Blackout recording (limiting dual display instruments, can be omitted without)
D
D represents a record with a power outage
The cumulative amount of pulse output
0
0 indicates cumulative amount pulse output function
Non-standard features
N
N represents a non-standard function
Instructions free of charge Phone: 400-676-6002