XSM Series Intelligent torque display table

XSM Series Intelligent torque display table
 

Product description:

Explanation:
① connected with various types of proximity switches, encoders, or various types of pulse measurement speed, torque transducer frequency, line speed, measurement frequency range 0.1Hz ~ 25kHz, the basic error of ± 0.02%, 5-digit LED display
② Dimensions: 160 * 80 (horizontal), 96 * 48 (horizontal), 96 * 96
③ instrument power 220V AC. (9 ~ 30) V DC
basic configuration:
Single display, external power supply for sensors (≥50mA)
extensions:
① alarm output: 160 * 80 specifications up to 4:00, 96 * 48 up to 2:00
② transmission output
③ Communication Interface: RS 232 or RS 485
Selection Tables

content
Code Description
XSM /
Single display, external power supply for sensors (≥50mA)
shape
size
A―
160 (W) * 80 (H) * 125 (L)
B―
96 (W) * 96 (H) * 112 (L)
C―
96 (W) * 48 (H) * 112 (L)
Panel form
H
Horizontal
F
Square
display method
(Color LED display according to the requirements of orders)
1
Measured value (green)
2
Measured value (green) + set value (red) (limited to A-type instrument)
3
Measured value (green) + measurement beam (green) (limited to A-type instrument)
Input signal
G
Standard suitable for NPN, PNP type voltage pulse. (4 ~ 20) mA 2 limit pulse, TTL pulse, etc.
M
mV type, suitable to the magnetic-electric proximity switches
Number of alarm points
T•
T0: No alarm T1 ~ T8: 1 ~ 8 point alarm
Transmission output
(Independent power supply, full isolation. 10 D / A, the error is less than ± 0.5%, or 12 D / A, the error is less than ± 0.2%)
A0
No output
A1
Current output (4 ~ 20) mA. (0 ~ 10) mA or (0 ~ 20) mA
A2
Voltage output (0 ~ 5) V, (1 ~ 5) V
A3
Voltage output (0 ~ 10) V
A4
Other output
External power supply
B0
No external power supply
B1
External supply 24V DC, error is less than ± 5%, 50mA
B2
External supply 12V DC, error is less than ± 5%, 50mA
B3
other
Communication Interface
(Independent power supply, full isolation, 2400 ~ 19.2K instrument addresses 0 to 99, the response delay is less than 500μs.)
S0
No communication interface
S1
RS-232 Interface
S2
RS-485 Interface
S3
RS-422 interface
S4
BCD code interface (limit A, B-type instrument) Note 2
Instrument Power
V0
220V AC
V1
24V DC
V2
12V DC
V3
other
Print function (limited to A, B-type instrument)
P
P represents print interface, can be omitted without
Prescale unit
F*
F * represents the prescale unit, can be omitted without.
Non-standard features
N
N represents a non-standard function