PC polycarbonate sun board income side bar / Edge / seal

PC polycarbonate sun board income side bar / Edge / seal

Product description:

Material: Aluminum Number of floors: Single Origin: Guangdong
Rating: Excellent Specification: 6m / support, special specifications can be customized large Open: automatic
Brands: Conrad Color: silver

PC dedicated lighting plate aluminum accessories (Aluminum batten / aluminum income side) is mainly used to install fastening PC board, high-quality solar panels installed accessories to make beautiful lighting sun roof cover, and can be more effective solution installed after construction leakage problem, and we can provide you with professional PC sheet up to more than 60 kinds of accessories, convenient different keel skeleton construction and installation, can meet all your needs, and have their own professional R & D personnel constantly improve and update products , so you can have more choices.

Income side is mainly used for solar panels at both ends sealed against dust, rain, insects into the plate hole, the impact plate life and appearance.

Material: 6063

Specification: 6m / support

4mm ~ 6mm small income side

8mm ~ 10mm large income side

12mm ~ 20mm three board income side

Also for large municipal projects; greenhouse projects; I introduced thickness adjustable snap-on the income side (for any thickness of PC sun panels, polycarbonate panels)

Sun panels Installation Notes

Plate Installation recommendations:

Must ensure that the skeleton formation and cleaning 1. Before installation;

2. The first check the size of the plate and cut the amount of expansion reserve eligibility; pay special attention to leave enough uniform expansion gap; calculated as follows:
Total expansion gap = expansion coefficient * maximum temperature difference before and after the local installation * sheet length
Expansion coefficient of 7.0 * 10-5 mm / mm. K

3. The thermal expansion coefficient of the plate and the support frame are different and need to stay in margin to withstand wind pressure, snow load, etc., so embedded in the amount to be set aside adequate, and thermal expansion and contraction of space. Usually the sheet edge extends into the cage 25mm or more, and at least two of ribs when installing fixed area; thermal expansion and contraction of 3mm per meter gap in general;

4. identify UV plate surface side; and to the side out installation; never allow the inward side of the UV installation;

5. When installing the sheet; protective film on the cover sheet of the joint compound will affect the binding and plate; so before installing the protective membrane around the lift plate 5 ~ 10cm; do not let the profile clamp protective film; but it can not lift too much; so as to avoid damage to the plate surface operations;
Note: Some workers when operating in the protective film sandwiched in profile; then draw lifted with a sharp tool and then printed; but often scratch the plate surface and cause damage to the plate;

6. Under cold-formed hollow plate installed, the bending radius of not less than 175 times the sheet thickness;

Hollow sheet only along the direction of the curved ribs;

Hollow plate tilt should be installed along the direction of the ribs, it is conducive to the export of condensate;

7. The board shall be fixed directly self drilling screw; shall reaming; all drilling diameter should be larger than the bolt diameter; leaving expansion and contraction gap; therefore when the material plate openings; aperture should be larger than the screw diameter 50%; avoid locking screws in the curved portion; avoid cracking plate;

8. The self-tapping force should be uniform when screwed ensure genuine compaction profile sealing strip and plate;

9. All pores should be filled in neutral sealant, neutral sealant and adhesive coating the exposed parts to prevent the infiltration of detergent edge, to prevent delay onset of crack; when found defective installation, site of leakage may occur in may be sealant compensate. Selection to choose the cured sealant remains soft, low modulus, elongation greater than 50% neutral weathering silicone rubber, before sizing must make aluminum and sheet surfaces clean and dry , so that no oil, dust, water vapor, dew and other debris, sizing should be uniform, smooth surface layer, and can not be uniform cross-section dimensions intermittent phenomenon; pay special attention to the neutral sealant used must advance Compatibility test sheet to avoid chemical reaction with the plate;

10. The center hole of the sheet edge spacing should be greater than or equal 5cm;

11. The whole process is strictly prohibited plate installation foot pedal surface, shall be used across the plate Moveable pedal operation;

12. PC board cut length must be greater than the width before bending;

13. Plate immediately after installation requirements torn off the protective film, as a result of construction of the special requirements of the protection board, also must first torn off protective film, and then re-cover;

14. After installing the plate should be a self-test, in particular, should seriously do spray test, check for leaks and, if leakage hazard should be eliminated, and then check the appearance quality;