Product parameters:

  • Brand: Jitai
  • Model: JT-35
  • Applicable object: high pressure
  • Electronic and electrical product type: contact type


Serial number

Pilot projects unit Voltage rating test parameters Remarks
3KV 6KV 10KV 35KV 110KV 220KV 500KV
1 Start voltage KV <0.7 <1.5 <2.5 <8 <25 <40 <60 contact
2 Back voltage Electric shock that is, from the power that stop
3 Checking the response distance Mm <5 <5 <10 <15 <60 <100 <500 qualified
4 Leakage current ΜA <30 <30 <30 <30 <30 <30 <30 qualified
5 Charge sound intensity DB > 75 > 75 >> 75 > 75 > 75 > 75 > 75 Background noise 50 dB, sound clearly discernible
6 DC voltage test KV 3 6 10 35 110 220 500 DC voltage test, do not have electricity display
7 Inspecting light intensity 1X 53600 53600 53600 53600 53600 53600 53600 qualified
8 Anti - arc test KV 3.6 7.2 12 42 130 260 600 The strongest arc test for 1 minute
9 Induced voltage test KV 3 Parallel rack two wires (20mm long 600mm pitch 1000mm, a power, a no electricity, no electricity on the wire is not tested electricity test signal
10 Anti - short circuit test KV 3.6 7.2 12 42 88 176 400 No breakdown occurs
11 Frequency withstand voltage test KV 40 40 40 150 250 450 640 Such as the breakdown pressure per 300mm pressure 40KV qualified
12 Temperature test Lt; 0 & gt; C -30+45 -30+45 -30+45 -30+45 -30+45 -30+45 -30+45 ± 5 hours of normal operation
13 Humidity test % 95% 95% 95% 95% 95% 95% 95% Working properly
14 Life test Times 5000 5000 5000 5000 5000 5000 5000 Working properly
15 Free fall Times 3 3 3 3 3 3 3 Electroscope from the cement floor one meter high drop normal work
16 Impact test Times 1000 1000 1000 1000 1000 1000 1000 Working properly
17 In-phase interference KV <1.2 <2.4 <4 <14 <44 <88 <200 qualified
18 Inverse interference KV > 1.8 > 3.6 > 6 > 21 > 66 > 132 > 300 qualified
19 working environment Indoor and outdoor
20 Operating Voltage V 6 6 6 6 6 6 6 AG13 silver oxide battery 4
21 Quiescent Current ΜA <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 qualified
22 Dynamic current MA <15 <15 <15 <15 <15 <15 <15 qualified
23 Dynamic power consumption W <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 <0.1 qualified
24 Rated time test KV 3 6 10 35 110 220 500 5 minutes sound and light display normal

The electroscope is the power system and industrial and mining enterprises operating the necessary safety tools, it is used to detect 0.1kV-10kV lines or equipment with operating frequency voltage to ensure that the staff in the power outage maintenance of personal safety.