[Electronic and Electrical] - [Instrumentation]

Fluke Fluke 59 Handheld Infrared Thermometer |

Fluke Fluke 59 Handheld Infrared Thermometer |
Product code: 13033100030
Unit price 43.88$
Sold quantity 440
Available stock 33

Product parameters:

  • Brand: FLUKE / Fluke
  • Model: Fluke 59 Handheld Infrared Thermometer
  • Item No .: 3520129
  • Decoration and construction content: installation works


Fluke 59 Handheld Infrared Thermometer

Fluke 59 is a tool that helps electrical engineers perform daily electrical maintenance and commissioning. It provides a quick and easy way to detect surface temperature of objects quickly and accurately, Its compact and compact design makes it easier for users to carry and get started, while Fluke 59 adheres to Fluke infrared thermometer product high repeatability, low scattering, high energy level, high durability characteristics, reflects the Fluke precision of the temperature High demand, more adapt to the industrial environment in the precise temperature measurement.

Features
Key advantages
  • Temperature range - 18 ° C to 275 ° C
  • Accuracy ± 2% of reading or ± 2 ° C
  • Distance coefficient ratio 8: 1 (90% energy level)
  • Repetitive reading ± 1% or ± 1 ° C
  • Single point laser aiming
  • Automatic reading is held for 7 seconds
  • Fulu 'class' Speak
    Optical resolution (D: S)
    That is, the ratio of the probe to the target diameter, where D is the distance between the thermometer and the measured target, S refers to the diameter of the temperature field of view, the ratio of the two is called the optical resolution if the temperature distance farther , The smaller the target, the higher the resolution of the thermometer should be selected
    Emissivity
    Is the ability of the object to radiate infrared energy, the value is the actual physical and the same temperature blackbody radiation ability ratio, the vast majority of common object emissivity of 0.95, metal, or special plastic and other different materials emissivity is not 0.95, emissivity continuous Adjustable to make the measurement more accurate, if you can not change the emissivity, with a known emissivity paint (black paint) or insulation tape attached to the target surface, by adjusting the measurement of black paint or insulation tape position temperature, while the instrument emissivity Can be set to 0.95, so as to accurately measure the object temperature
    Measure the bright surface
    When measuring the surface temperature of the luminous object, such as aluminum and stainless steel, the surface reflection will affect the degree of infrared thermometer, before the reading temperature can be attached to the metal surface non-reflective tape, so as to detect the temperature at the tape to prevent the surface Reflect the impact of accuracy
    Double laser:
    62max + has a rotating double laser, you can identify the area being measured; as long as the measured object size is greater than the distance between two laser points, you can get accurate measurement
    IP protection
    IP (INGRESS PROTECTION) The degree of protection system is drafted by IEC (INTERNATIONAL ELECTROTECHNICAL COMMISSION). The electrical appliances are classified according to their characteristics of dust and moisture. The objects referred to here include tools, human fingers, etc. Electrical protection within the part, so as not to shock. IP protection level is composed of two figures, the first number that electrical dust, to prevent the invasion of foreign objects, the first two figures that electrical moisture, water intrusion The greater the number, the higher the degree of protection.









    Features
    Key advantages
  • Temperature range - 18 ° C to 275 ° C
  • Accuracy ± 2% of reading or ± 2 ° C
  • Distance coefficient ratio 8: 1 (90% energy level)
  • Repetitive reading ± 1% or ± 1 ° C
  • Single point laser aiming
  • Automatic reading is held for 7 seconds
  • backlight
  • Fulu 'class' Speak
    Optical resolution (D: S)
    That is, the ratio of the probe to the target diameter, where D is the distance between the thermometer and the measured target, S refers to the diameter of the temperature field of view, the ratio of the two is called the optical resolution if the temperature distance farther , The smaller the target, the higher the resolution of the thermometer should be selected
    Emissivity
    Is the ability of the object to radiate infrared energy, the value is the actual physical and the same temperature blackbody radiation ability ratio, the vast majority of common objects emissivity of 0.95, metal, or special plastic and other different materials emissivity is not 0.95, emissivity continuous Adjustable to make the measurement more accurate, if you can not change the emissivity, with a known emissivity paint (black paint) or insulation tape attached to the target surface, by adjusting the measurement of black paint or insulation tape position temperature, while the instrument emissivity Can be set to 0.95, so as to accurately measure the temperature of the object
    Measure the bright surface
    When measuring the surface temperature of the luminous object, such as aluminum and stainless steel, the surface reflection will affect the degree of infrared thermometer, before the reading temperature can be attached to the metal surface non-reflective tape, so as to detect the temperature at the tape to prevent the surface Reflect the impact of accuracy
    Double laser:
    62max + has a rotating double laser, you can identify the area being measured; as long as the measured object size is greater than the distance between two laser points, you can get accurate measurement
    IP protection
    IP (INGRESS PROTECTION) The degree of protection system is drafted by IEC (INTERNATIONAL ELECTROTECHNICAL COMMISSION). The electrical appliances are classified according to their characteristics of dust and moisture. The objects referred to here include tools, human fingers, etc. Electrical protection within the part, so as not to shock. IP protection level is composed of two figures, the first number that electrical dust, to prevent the invasion of foreign objects, the first two figures that electrical moisture, water intrusion The greater the number, the higher the degree of protection.









    Technical specifications
    Why choose Fluke Infrared Thermometer
    What is the value of the impact? What is the value of the Fluke Thermometer?

    Worries 1:
    Sudden change in temperature?

    The sudden change of the ambient temperature will have an effect on the accurate measurement of the infrared thermometer, and the typical scenario is winter or summer. The inspectors are measured indoors and outdoors. If you want to obtain accurate results, you will need to wait for some time at the test site. Infrared thermometer and field temperature closer to the measurement, called thermal shock recovery. Test data show that Fluke thermometer good heat shock, reading only in the accuracy range beating. Fluke thermometer inherited the old Leitai 30 Year heat dissipation research and development experience, with excellent heat conduction and heat exchange design, to ensure accurate.
    Worries 2
    Accidental fall, but also prospective?

    As the thermometer contains the optical system, accidental fall may not only damage the appearance, but also may affect its accuracy. Fluke thermometer 62MAX / + and MT4 MAX / +, respectively, through the 3 m and 1 m drop test, rigorous industry Structural design to ensure that the impact of the body to minimize the damage to its optical systems and circuits
    Worries 3
    Strong wet environment, but also prospective?

    Infrared thermometer instrument ah use, but also encounter the challenges of temperature changes in the relative humidity of more than 90% of the environment, the infrared thermometer can remain accurate? Fluke each model are used 'Six Sigma' principle In the extreme environment for hundreds of tests and debugging, 100% to ensure that each test machine can achieve the nominal size.
    Worries 4
    Electromagnetic interference, but also accurate?

    Industrial field of electromagnetic interference everywhere, such as various types of radio transmission equipment, electrical equipment, electronic equipment, etc .. Fluke thermometer selection of advanced substrate, effectively reduce the electromagnetic interference and high humidity on the accurate impact.
    Worries 5:
    Repeated measurement, but also prospective?

    The same measured object in a period of time constant surface temperature, with the same thermometer to measure how much read the deviation of the smaller, indicating the higher reproducibility of the thermometer. High repeatability is very important to the user: 1 , 2, the confidence interval of accumulated empirical data. Fluke thermometer uses expensive operational amplifiers and strict circuit board to ensure 0.5% of the measurement repeatability.









    Simple operating instructions