[Electronic and Electrical] - [Instrumentation]

Fluke Multimeter FLUKE18B + Digital Multimeter F18B + Fluke Digital Multimeter | Multimeter

Fluke Multimeter FLUKE18B + Digital Multimeter F18B + Fluke Digital Multimeter | Multimeter
Product code: 12072800030
Unit price 197.67$
Sold quantity 65
Available stock 75

Product parameters:

  • Item: FLUKE18B
  • Decoration and construction content: installation works
  • Work: Digital display
  • Accuracy: three and a half
  • Brand: FLUKE / Fluke
  • Model: Fluke18B


Fluke 18B + Fluke always offers you superior quality.

Use the 18B + multimeter to check and test most of the electronics. The instrument is easy to use and has a significant improvement over the original Fluke 18B. For anyone engaged in electronic maintenance and manufacturing settings. Whether you always want to have a Taiwan Fluke digital multimeter, or has been looking for the reasons for the upgrade, Fluke 18B + can meet your needs.

  • 600 V Cat III Safety Design Indicators
  • The display range is 50% larger and the backlight is bright white
  • Smart LED test lighting LED (regardless of polarity), allows you to test the LED in two modes:
    • DMM LED socket test mode
    • LED test mode on UUT (PCBA) (using test leads)
  • Voltage, resistance, current, capacitance
  • Diode test, data retention
  • Frequency and duty cycle
  • The AC and DC current measurements of the input terminals are 10A



Precision specifications

After calibration, the accuracy can be maintained for 1 year. The operating temperature is 18 ° C to 28 ° C and the relative humidity is 0% to 75%. The accuracy specifications are as follows: ± ((% of reading) + (least significant digits)).
Features Range Resolution Accuracy
AC voltage
(40 Hz to 500 Hz)1
4.000 V
40.00 V
400.0 V
1000 V


0.001 V
0.01 V
0.1 V
1 V


1.0 % + 3
DC voltage 4.000 V
40.00 V
400.0 V
1000 V


0.001 V
0.01 V
0.1 V
1 V


0.5 % + 3
AC voltage (millivolts) 400.0 mV 0.1 mV 3.0 % + 3
DC voltage (millivolts) 400.0 mV 0.1 mV 1.0 % + 10
Diode test2 2.000 V 0.001 V 10%
resistance
(ohm)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ




0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ




0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5% + 3




capacitance3 40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF




0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF




2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5




frequency1
Hz
(10 Hz - 100 kHz)

50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz



0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz



0.1 % + 3
Duty cycle1 1% to 99% 0.1 % 1% typical case l 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
AC current
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
DC current μA 400.0 μA
4000 μA
0.1 μA
1 μA
1.5 % + 3
DC current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5 % + 3
DC current 4.000 A
10.00 A
0.001 A
0.01 A
1.5 % + 3
1All current, frequency, and duty cycles range from 1% to 100% of the range. No input value below 1% of the range is specified.
2Typically, the open-circuit test voltage is 2.0 V and the short-circuit current is less than 0.6 mA.
3The specifications do not include errors in the test lead capacitance and capacitor plate (the maximum error is 1.5 nF when measuring 40 nF).
4Usually means a frequency of 50 Hz or 60 Hz and a duty cycle of between 10% and 90%.