Genuine Fluke Digital Compact Multimeter

Genuine Fluke Digital Compact Multimeter
 

Product description:

Product parameters:

  • Item No .: F101
  • Color classification: F101
  • Decoration and construction content: hydropower projects
  • Work: digital display
  • Accuracy: Other
  • Brand: FLUKE / Fluke
  • Model: F101


Fluke 101kit Equipped with SmartStrap ™ intelligent magnetic multi-purpose strap

Electrical Specifications
AC voltage (40-500Hz) Range 600.0 mV
6.000 V
60.00 V
600.0 V


Resolution 0.1 mV
0.001 V
0.01 V
0.1 V


Precision 3.0% ± 3 digits
1.0% ± 3 positions
DC voltage Range 6.000 V
60.00 V
600.0 V

Resolution 0.001 V
0.01 V
0.1 V

Precision 0.5% ± 3 positions
Resistance (ohms) Range 400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ




Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ




Precision 0.5% ± 3 positions
0.5% ± 2 digits
0.5% ± 2 digits
0.5% ± 2 digits
0.5% ± 2 digits
1.5% ± 3 digits




capacitance Range 50.00 nF
500.0 nF
5.000 μF
50.00 μF
500.00 μF
1000.0 μF




Resolution 0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF



Duty cycle Range 0.1% to 99.9%
Resolution 0.10%
General technical specifications
CAT level CAT III 600 V
AC voltage range 600.0 V
DC voltage range 600.0 V
Resistance Range 40.00 MΩ
Automatic shut-down Y
Continuity Y
Capacitors 100.0 μF
frequency 100.0 kHz
maintain no
Duty cycle Yes
size 130 mm x 65 mm x 27 mm
weight 160 g
battery Two AAA batteries
warranty period 1 year
Environmental specifications
Operating temperature 0 ° C to +40 ° C
Storage temperature -30 ° C to +60 ° C
Working humidity Non-condensing (<10 ° C)
<= Relative humidity 90% (10 ° C to 30 ° C)
<= Relative humidity 75% (30 ° C to 40 ° C)
(No condensation)


Operating humidity, 40 MΩ Relative humidity 80% (10 ° C to 30 ° C), relative humidity 70% (30 ° C to 40 ° C)
Working altitude 2000 m
Storage Elevation 12000 m
Degree of protection According to IEC 60529, the degree of protection is IP 40
Vibration requirements MIL-PRF-28800F Class 2
Drop test requirements -10 ° C and 1 meter above the ground, according to IEC-61010-1, and Fluke SOP 39.1 for portable hand-held devices
The shipping box drop test is based on the Fluke SOP 39.
EMI, RFI, EMC All must be met
IEC / EN 61326-1 requirements
Absorption / corrosion According to the requirements of Fluke SOP 39.1
Temperature Coefficient Accuracy above 0.1 ° C per ° C above 28 ° C or below 18 ° C



  • The appearance of new, small size, comfortable grip, weighing only 160g, can easily into the pocket or easy to carry
  • Automatic power saving mode
  • Automatic range test, test more convenient and more rapid; while reducing the number of disk rotation, extending instrument life
  • Data hold function, easier to read the measurement results
  • Meet the IEC61010-1 CATIII 600V security rating standards, users can test a wider range of occasions and test, and test more secure, that protects the user investment, but also to ensure the safety of personnel and equipment
  • Fluke SmartStrap ™ Smart Magnetic Multipurpose Strap (Fluke101kit is standard, Fluke-101 is optional) Designed to be unique and novel, adsorption, suspension, support, heart to use, make the instrument carry and carry out the test more easily